Literature DB >> 18464266

Effect of surface topography on removal of cortical bone screws in a novel sheep model.

Alexandra I Pearce1, Simon G Pearce, Karsten Schwieger, Stefan Milz, Erich Schneider, Charles W Archer, R Goeff Richards.   

Abstract

Difficulty in removing implants used in trauma patients can be a complication, and increased bone-implant adhesion likely is a major contributing factor. In vitro studies have shown that surface morphology of implant materials has the ability to influence cellular responses, with polished surfaces decreasing the potential for mineralization. This study examined the effect of polishing commercially pure titanium (cpTi) and the titanium alloy TAN on the removal torque and percentage bone-implant contact in cortical and cancellous bone of sheep. Polishing had a significant effect on both removal torque and percentage bone-implant contact, with the polished implants demonstrating a lower removal torque in both cortical and cancellous bone. Polished cpTi and stainless steel were similar in terms of surface roughness and removal torque. However, polished TAN, which was not as smooth as polished cpTi, did not show the same low level for reducing removal torque. Improved polishing of TAN should reduce the removal torque further. The results of the study show that polishing is promising in improving the ease of implant removal after fracture fixation and repair. (c) 2008 Orthopaedic Research Society.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18464266     DOI: 10.1002/jor.20665

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  8 in total

1.  Infection in fracture fixation: can we influence infection rates through implant design?

Authors:  T Fintan Moriarty; U Schlegel; S Perren; R Geoff Richards
Journal:  J Mater Sci Mater Med       Date:  2009-10-20       Impact factor: 3.896

2.  Indications for implant removal after fracture healing: a review of the literature.

Authors:  D I Vos; M H J Verhofstad
Journal:  Eur J Trauma Emerg Surg       Date:  2013-04-12       Impact factor: 3.693

3.  Technical complications during removal of locking screws from locking compression plates: a prospective multicenter study.

Authors:  N Schwarz; S Euler; M Schlittler; T Ulbing; P Wilhelm; G Fronhöfer; M Irnstorfer
Journal:  Eur J Trauma Emerg Surg       Date:  2013-06-04       Impact factor: 3.693

4.  Osseointegration and biocompatibility of different metal implants--a comparative experimental investigation in sheep.

Authors:  Michael Plecko; Christine Sievert; Daniel Andermatt; Robert Frigg; Peter Kronen; Karina Klein; Stefan Stübinger; Katja Nuss; Alexander Bürki; Stephen Ferguson; Ulrich Stoeckle; Brigitte von Rechenberg
Journal:  BMC Musculoskelet Disord       Date:  2012-03-08       Impact factor: 2.362

5.  Osteoblasts Interaction with PLGA Membranes Functionalized with Titanium Film Nanolayer by PECVD. In vitro Assessment of Surface Influence on Cell Adhesion during Initial Cell to Material Interaction.

Authors:  Antonia Terriza; José I Vilches-Pérez; Juan L González-Caballero; Emilio de la Orden; Francisco Yubero; Angel Barranco; Agustín R Gonzalez-Elipe; José Vilches; Mercedes Salido
Journal:  Materials (Basel)       Date:  2014-03-04       Impact factor: 3.623

6.  Manual polishing of 3D printed metals produced by laser powder bed fusion reduces biofilm formation.

Authors:  Marissa McGaffey; Alex Zur Linden; Nathanael Bachynski; Michelle Oblak; Fiona James; J Scott Weese
Journal:  PLoS One       Date:  2019-02-27       Impact factor: 3.240

7.  Screw stripping and its prevention in the hexagonal socket of 3.5-mm titanium locking screws.

Authors:  Hyo-Jin Lee; Young Uk Park; Sung Jae Kim; Hyong Nyun Kim
Journal:  Sci Rep       Date:  2021-10-29       Impact factor: 4.379

8.  Reduced fibroblast adhesion and proliferation on plasma-modified titanium surfaces.

Authors:  Sebastian Kuhn; Jennifer Kroth; Ulrike Ritz; Alexander Hofmann; Christian Brendel; Lars Peter Müller; Renate Förch; Pol Maria Rommens
Journal:  J Mater Sci Mater Med       Date:  2014-07-24       Impact factor: 3.896

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.