Literature DB >> 18462202

Temporary implant-supported prosthesis for immediate loading according to a chair-side concept: technical note and results from 37 consecutive cases.

Pär-Olov Ostman1, Mats Hellman, Lars Sennerby, Ann Wennerberg.   

Abstract

BACKGROUND: During the last years, focus has been paid to implant treatment using immediate function protocols, and different approaches to provide patients with temporary constructions have been presented. Most of these techniques involve dental technicians producing the temporary construction, for example, rebuilding existing dentures, acrylic bridges, etc.
PURPOSE: The purpose of this prospective clinical study was to evaluate the clinical outcome of a chair-side technique of a cost-effective temporary prosthesis. Fixture survival rate and risk of temporary bridge failure were analyzed.
MATERIALS AND METHODS: Thirty-seven partially or totally edentate patients (18 female and 19 male; mean age: 66.7 years) treated with chair-side manufactured temporary restorations (QuickBridge, BIOMET 3i, Palm Beach, Fl, USA) for immediate loading have been evaluated. The prostheses extended from two unit bridges supported by two implants to full-arch construction supported by six implants. The temporary prostheses were monitored from the day of surgery and delivery to the time of replacement with a permanent prosthetic construction 3 to 6 months later.
RESULTS: No implants were lost during the observation time. One (3%) temporary prosthesis fractured and additional two (6%) loosened during the follow-up time.
CONCLUSIONS: The study indicated that the tested chair-side concept for manufacturing of temporary prosthesis for immediate loading of dental implants is a viable approach.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18462202     DOI: 10.1111/j.1708-8208.2007.00069.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  2 in total

1.  Immediate loading of one-piece implants in conjunction with a modified technique of inferior alveolar nerve lateralization: 10 years follow-up.

Authors:  Riham Eldibany; Joaquin G Rodriguez
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-01-13

2.  Semirigid cantilever extension system for splinting implants: a clinical report.

Authors:  Raissa Micaella Marcello Machado; Luciana de Rezende Pinto; Otacílio Luiz Chagas Júnior; Fernanda Faot
Journal:  Case Rep Dent       Date:  2014-08-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.