Literature DB >> 18460702

Invasive measurements of atrioventricular conduction parameters prior to and following ventricular septal defect closure with the amplatzer device.

Euloge Kouadio Kramoh1, Nagib Dahdah, Anne Fournier, Shubhayan Sanatani, Martin Hosking, Joaquim Miró.   

Abstract

BACKGROUND: Because of anatomical proximity, closure of paramembranous ventricular septal defect (pm-VSD) with an Amplatzer occluder has the potential to affect the atrioventricular (AV) conduction system. PATIENTS AND METHODS: Electrophysiology studies (EPS) were performed prior to and following closure of the pm-VSD in 19 children aged 8.9 +/- 4.5 years. Data from electrocardiograms, Holter monitoring and exercise tests before intervention and at follow up (1.9 +/- 0.8 years) were reviewed.
RESULTS: There were no EPS catheter-induced complications. Incidence of total conduction anomalies was 31.6% with 21% of patients having permanent conduction anomalies. Complete AV block was not recorded in any subject and transitory 1st-degree AV block occurred in 2 patients. Permanent complete right bundle branch block was observed in 2 patients and incomplete right bundle branch block in 2 others. Prolongation in EPS parameters was significant for His ventricle interval (p = 0.017). Otherwise, EPS parameters with increased measurements > 15% were observed in 18 patients (95%). Prolongation of retrograde Wenckebach cycle length was predictive of new onset conduction abnormalities (p = 0.003). Other parameters changes did not correlate with the observed conduction disturbances however. With respect to device implantation characteristics, a large Amplatzer device was the only predictive risk factor for new conduction abnormalities (p = 0.03).
CONCLUSION: Closure of pm-VSD with an Amplatzer device promotes relative changes of the AV conduction system, mainly with large devices. In our limited series, these changes have no apparent clinical impact in the immediate and intermediate terms.

Entities:  

Mesh:

Year:  2008        PMID: 18460702

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  3 in total

1.  Retrograde closure of perimembranous ventricular septal defect using muscular ventricular septal occluder: a single-center experience of a novel technique.

Authors:  Kalyanasundaram Muthusamy
Journal:  Pediatr Cardiol       Date:  2014-08-20       Impact factor: 1.655

Review 2.  Recent advances in managing septal defects: ventricular septal defects and atrioventricular septal defects.

Authors:  P Syamasundar Rao; Andrea D Harris
Journal:  F1000Res       Date:  2018-04-26

3.  The Long-Term Change of Arrhythmias after Transcatheter Closure of Perimembranous Ventricular Septal Defects.

Authors:  Hongyan Zheng; Aiwen Lin; Li Wang; Yukai Xu; Zhiwei Zhang
Journal:  Cardiol Res Pract       Date:  2021-06-22       Impact factor: 1.866

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.