Literature DB >> 18456137

Evaluation of orthodontic mini-implant anchorage in premolar extraction therapy in adolescents.

Judah S Garfinkle1, Larry L Cunningham, Cynthia S Beeman, G Thomas Kluemper, E Preston Hicks, Mi-Ok Kim.   

Abstract

INTRODUCTION: The purpose of this study was to determine the success rate, positional stability, and patient evaluation of orthodontic mini-implants (OMIs).
METHODS: Thirteen patients (8 girls, 5 boys; average age, 14 years 10 months) were treated with 82 OMIs measuring 1.6 mm in diameter and 6 mm in length placed in the buccal alveoli (1 unloaded OMI and 1 loaded OMI per quadrant). The right or left side of each arch was randomly selected for immediate loading with up to 250 g of direct force; the contralateral side was loaded 3 to 5 weeks later. Serial impressions, clinical observations, and orthodontic maintenance were performed until adequate space closure was achieved.
RESULTS: The overall OMI success rate was 70.73%. As calculated with a mixed-model analysis, there was no statistically significant difference between the success rates of immediately loaded OMIs (80.0%) and delayed loaded OMIs (80.95%). The combined success rate for loaded OMIs (80.49%) was significantly higher than that of unloaded OMIs (60.98%). Patients' motivation for OMI treatment was primarily the desire to avoid headgear. Using a 100-mm visual analog scale, the patients indicated average scores of 54.77 for the amount of pain during OMI placement and 27.10 for the amount of pain during OMI removal.
CONCLUSIONS: OMIs are a predictable, effective, and well-tolerated anchorage source for adolescents. Neither the timing of force application nor the force itself precipitated failure of the OMIs. Orthodontic forces can be applied immediately to OMIs. Various anatomic and behavioral conditions unique to adolescents and a clinical learning curve can affect the success rate of OMIs.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18456137     DOI: 10.1016/j.ajodo.2006.04.053

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  22 in total

1.  Clinical evaluation of immediate loading of titanium orthodontic implants.

Authors:  S S Chopra; A Chakranarayan
Journal:  Med J Armed Forces India       Date:  2012-10-23

2.  Comparative evaluation of anchorage reinforcement between orthodontic implants and conventional anchorage in orthodontic management of bimaxillary dentoalveolar protrusion.

Authors:  S S Chopra; Manish Mukherjee; Rajat Mitra; Gagan Deep Kochar; Abhijeet Kadu
Journal:  Med J Armed Forces India       Date:  2016-03-02

Review 3.  Reinforcement of anchorage during orthodontic brace treatment with implants or other surgical methods.

Authors:  Safa Jambi; Tanya Walsh; Jonathan Sandler; Philip E Benson; Richard M Skeggs; Kevin D O'Brien
Journal:  Cochrane Database Syst Rev       Date:  2014-08-19

Review 4.  Comparison of anchorage capacity between implant and headgear during anterior segment retraction.

Authors:  F Li; H K Hu; J W Chen; Z P Liu; G F Li; S S He; S J Zou; Q S Ye
Journal:  Angle Orthod       Date:  2011-02-07       Impact factor: 2.079

5.  Osseointegration of orthodontic micro-screws after immediate and early loading.

Authors:  Linkun Zhang; Zhihe Zhao; Yu Li; Jiapei Wu; Leilei Zheng; Tian Tang
Journal:  Angle Orthod       Date:  2010-03       Impact factor: 2.079

6.  In vivo evaluation of immediately loaded stainless steel and titanium orthodontic screws in a growing bone.

Authors:  Kerstin Gritsch; Norbert Laroche; Jeanne-Marie Bonnet; Patrick Exbrayat; Laurent Morgon; Muriel Rabilloud; Brigitte Grosgogeat
Journal:  PLoS One       Date:  2013-10-04       Impact factor: 3.240

Review 7.  Systematic review of mini-implant displacement under orthodontic loading.

Authors:  Manuel Nienkemper; Jörg Handschel; Dieter Drescher
Journal:  Int J Oral Sci       Date:  2013-12-20       Impact factor: 6.344

8.  Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force.

Authors:  Ying-juan Lu; Shao-hai Chang; Jian-tao Ye; Yu-shan Ye; Yan-song Yu
Journal:  PLoS One       Date:  2015-12-14       Impact factor: 3.240

Review 9.  A Mini-review on the Effect of Mini-implants on Contemporary Orthodontic Science.

Authors:  Saeid Nosouhian; Mansour Rismanchian; Roya Sabzian; Elham Shadmehr; Hamid Badrian; Amin Davoudi
Journal:  J Int Oral Health       Date:  2015

Review 10.  Does cortical thickness influence the primary stability of miniscrews?: A systematic review and meta-analysis.

Authors:  Mariana Marquezan; Cláudia Trindade Mattos; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza; Lucianne Cople Maia
Journal:  Angle Orthod       Date:  2014-04-02       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.