Literature DB >> 18454286

Two immunoassay formats for fully automated CRP detection in human serum.

Christiane Albrecht1, Nina Kaeppel, Guenter Gauglitz.   

Abstract

Immunoassays are a proven approach towards fast, sensitive, cost-effective and easy-to-use analytical systems which are able to measure a variety of interesting analytes, especially in medical diagnostics. Herein, we report two assay formats, binding inhibition and sandwich assay format, for detection of C-reactive protein (CRP) in human serum. Both assays were characterised and compared with respect to their suitability and adaption into a complete sensor system. An automated, optical biosensor system, based on evanescent field technology, was used to carry out a full threefold calibration in each case. Owing to the resulting working ranges, 0.044-2.9 mg L(-1) and 0.13-22.9 mg L(-1), respectively, the assays qualify for use in detecting high-sensitivity CRP (C-reactive protein).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18454286     DOI: 10.1007/s00216-008-2093-x

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

Review 1.  Evanescent wave fluorescence biosensors: Advances of the last decade.

Authors:  Chris Rowe Taitt; George P Anderson; Frances S Ligler
Journal:  Biosens Bioelectron       Date:  2015-07-20       Impact factor: 10.618

Review 2.  Array Biosensor for Toxin Detection: Continued Advances.

Authors:  Chris Rowe Taitt; Lisa C Shriver-Lake; Miriam M Ngundi; Frances S Ligler
Journal:  Sensors (Basel)       Date:  2008-12-15       Impact factor: 3.576

3.  Development of a Cuvette-Based LSPR Sensor Chip Using a Plasmonically Active Transparent Strip.

Authors:  Seo Yeong Oh; Nam Su Heo; Vivek K Bajpai; Sung-Chan Jang; Gyeongsik Ok; Youngjin Cho; Yun Suk Huh
Journal:  Front Bioeng Biotechnol       Date:  2019-11-01

4.  Novel Regeneration Approach for Creating Reusable FO-SPR Probes with NTA Surface Chemistry.

Authors:  Jia-Huan Qu; Karen Leirs; Remei Escudero; Žiga Strmšek; Roman Jerala; Dragana Spasic; Jeroen Lammertyn
Journal:  Nanomaterials (Basel)       Date:  2021-01-13       Impact factor: 5.076

5.  An integrated device for fast and sensitive immunosuppressant detection.

Authors:  Sara Tombelli; Cosimo Trono; Simone Berneschi; Chiara Berrettoni; Ambra Giannetti; Romeo Bernini; Gianluca Persichetti; Genni Testa; Guillermo Orellana; Francesca Salis; Susanne Weber; Peter B Luppa; Giampiero Porro; Giovanna Quarto; Markus Schubert; Marcel Berner; Paulo P Freitas; Susana Cardoso; Fernando Franco; Vânia Silverio; Maria Lopez-Martinez; Urs Hilbig; Kathrin Freudenberger; Günter Gauglitz; Holger Becker; Claudia Gärtner; Mark T O'Connell; Francesco Baldini
Journal:  Anal Bioanal Chem       Date:  2021-12-22       Impact factor: 4.142

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.