Literature DB >> 184523

Precision and accuracy of foundry dust exposure estimates from air sampling data.

A Tossavainen, A Kokko.   

Abstract

Errors in the sampling methods and in the determination of respirable size quartz in foundry dust have been evaluated and discussed. In general, the total precision of dust sampling and analysis was better than 20%. The term "exposure dose" is introduced and defined. The temporal variation associated with measuring exposure dose is assessed with reference to the use of a log-normal distribution of air sampling results. The logarithmic standard deviations of dust concentrations at fixed sites and jobs are calculated.

Mesh:

Substances:

Year:  1976        PMID: 184523     DOI: 10.5271/sjweh.2839

Source DB:  PubMed          Journal:  Scand J Work Environ Health        ISSN: 0355-3140            Impact factor:   5.024


  2 in total

1.  Serum and urinary vanadium of workers processing vanadium pentoxide.

Authors:  M Kiviluoto; L Pyy; A Pakarinen
Journal:  Int Arch Occup Environ Health       Date:  1981       Impact factor: 3.015

2.  Determination and Prediction of Respirable Dust and Crystalline-Free Silica in the Taiwanese Foundry Industry.

Authors:  Ching-Tang Kuo; Fen-Fen Chiu; Bo-Ying Bao; Ta-Yuan Chang
Journal:  Int J Environ Res Public Health       Date:  2018-09-25       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.