Time-dependent contamination of opened sterile operating-room trays.

David J Dalstrom1, Indresh Venkatarayappa, Alison L Manternach, Marilyn S Palcic, Beth A Heyse, Michael J Prayson.   

Abstract

BACKGROUND: There are no clear guidelines for how long a sterile operating-room tray can be exposed to the open environment before the contamination risk becomes unacceptable. The purpose of this study was to determine the time until first contamination and the rate of time-dependent contamination of sterile trays that had been opened in a controlled operating-room environment. We also examined the effect of operating-room traffic on the contamination rate.
METHODS: Forty-five sterile trays were opened in a positive-air-flow operating room. The trays were randomly assigned to three groups. All trays were opened with use of sterile technique and were exposed for four hours. Culture specimens were obtained immediately after opening and every thirty minutes thereafter during the study period. Group 1 consisted of fifteen trays that were opened and left uncovered in a locked operating room (i.e., one with no traffic). Group 2 was identical to Group 1 with the addition of single-person traffic flowing in and out of the operating room from a nonsterile corridor every ten minutes. Group 3 included fifteen trays that were opened, immediately covered with a sterile surgical towel, and then left uncovered in a locked operating room (i.e., one with no traffic).
RESULTS: Three of the thirty uncovered trays (one left in the operating room with traffic and two left in the room with no traffic) were found to be contaminated immediately after opening. After those three trays were eliminated, the contamination rates recorded for the twenty-seven uncovered trays were 4% (one tray) at thirty minutes, 15% (four) at one hour, 22% (six) at two hours, 26% (seven) at three hours, and 30% (eight) at four hours. There was no difference in survival time (p = 0.47) or contamination rate (p = 0.69) between the uncovered trays in the room with traffic and those in the room without traffic. The covered trays were not contaminated during the testing period. The survival time for those trays was significantly longer (p = 0.03) and the contamination rate was significantly lower (p = 0.02) than those for the uncovered trays.
CONCLUSIONS: Culture positivity correlated directly with the duration of open exposure of the uncovered operating-room trays. Light traffic in the operating room appeared to have no impact on the contamination risk. Coverage of surgical trays with a sterile towel significantly reduced the contamination risk.

Entities:  

Mesh:

Year:  2008        PMID: 18451394     DOI: 10.2106/JBJS.G.00689

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  25 in total

1.  The linear cutting stapler may reduce surgical time and blood loss with muscle transection: a pilot study.

Authors:  Daniel C Allison; Elke R Ahlmann; Anny H Xiang; Lawrence R Menendez
Journal:  Clin Orthop Relat Res       Date:  2009-05-19       Impact factor: 4.176

Review 2.  Mobile phones in the orthopedic operating room: Microbial colonization and antimicrobial resistance.

Authors:  Nada Qaisar Qureshi; Syed Hamza Mufarrih; Seema Irfan; Rizwan Haroon Rashid; Akbar Jaleel Zubairi; Anum Sadruddin; Israr Ahmed; Shahryar Noordin
Journal:  World J Orthop       Date:  2020-05-18

Review 3.  Prevention of fracture-related infection: a multidisciplinary care package.

Authors:  Willem-Jan Metsemakers; Jolien Onsea; Emilie Neutjens; Ester Steffens; Annette Schuermans; Martin McNally; Stefaan Nijs
Journal:  Int Orthop       Date:  2017-08-22       Impact factor: 3.075

4.  Are bone and serum cefazolin concentrations adequate for antimicrobial prophylaxis?

Authors:  Koji Yamada; Kunihiro Matsumoto; Fumiaki Tokimura; Hiroshi Okazaki; Sakae Tanaka
Journal:  Clin Orthop Relat Res       Date:  2011-10-04       Impact factor: 4.176

5.  Risk factors for postoperative complication after spinal fusion and instrumentation in degenerative lumbar scoliosis patients.

Authors:  Honghui Tang; Jianfei Zhu; Feng Ji; Shouguo Wang; Yue Xie; Haodong Fei
Journal:  J Orthop Surg Res       Date:  2014-03-07       Impact factor: 2.359

6.  Thirty-Day Morbidity Associated with Pelvic Fixation in Adult Patients Undergoing Fusion for Spinal Deformity: A Propensity-Matched Analysis.

Authors:  Parth Kothari; Sulaiman Somani; Nathan J Lee; Javier Z Guzman; Dante M Leven; Branko Skovrlj; Jeremy Steinberger; Jun Kim; Samuel K Cho
Journal:  Global Spine J       Date:  2017-02-01

7.  Covering surgical instruments with single- or double-layer drape pending surgery: an experimental study in a perioperative setting.

Authors:  Maria Qvistgaard; Sofia Almerud-Österberg; Jenny Lovebo
Journal:  J Infect Prev       Date:  2020-12-08

8.  The role of packaging size on contamination rates during simulated presentation to a sterile field.

Authors:  Tony Trier; Nora Bello; Tamara Reid Bush; Laura Bix
Journal:  PLoS One       Date:  2014-07-08       Impact factor: 3.240

9.  Antibiotic Resistance of Commensal Staphylococcus aureus and Coagulase-Negative Staphylococci in an International Cohort of Surgeons: A Prospective Point-Prevalence Study.

Authors:  Mario Morgenstern; Christoph Erichsen; Simon Hackl; Julia Mily; Matthias Militz; Jan Friederichs; Sven Hungerer; Volker Bühren; T Fintan Moriarty; Virginia Post; R Geoff Richards; Stephen L Kates
Journal:  PLoS One       Date:  2016-02-03       Impact factor: 3.240

10.  Improving operating efficiency with emphasis on prosthetic surgery.

Authors:  Neil Baum; David F Mobley; Paul Perito
Journal:  Asian J Androl       Date:  2015 Jul-Aug       Impact factor: 3.285

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.