Monte Carlo dose calculation of segmental IMRT delivery to a moving phantom using dynamic MLC and gating log files.

Mike Oliver1, Robert Staruch, Adam Gladwish, Jeff Craig, Jeff Chen, Eugene Wong.   

Abstract

Respiratory gating is emerging as a tool to limit the effect of motion for liver and lung tumors. In order to study the impact of target motion and gated intensity modulated radiation therapy (IMRT) delivery, a computer program was developed to simulate segmental IMRT delivery to a moving phantom. Two distinct plans were delivered to a rigid-motion phantom with a film insert in place under four conditions: static, sinusoidal motion, gated sinusoidal motion with a duty cycle of 25% and gated sinusoidal motion with duty cycle of 50% under motion conditions of a typical patient (A = 1 cm, T = 4 s). The MLC controller log files and gating log files were retained to perform a retrospective Monte Carlo dose calculation of the plans. Comparison of the 2D planar dose distributions between simulation and measurement demonstrated that our technique had at least 94% of the points passing gamma criteria of 3% for dose difference and 3 mm as the distance to agreement. This note demonstrates that the use of dynamic multi-leaf collimator and respiratory monitoring system log files together with a fast Monte Carlo dose calculation algorithm is an accurate and efficient way to study the dosimetric effect of motion for gated or non-gated IMRT delivery on a rigidly-moving body.

Entities:  

Mesh:

Year:  2008        PMID: 18448873     DOI: 10.1088/0031-9155/53/10/N03

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Dynamic gating window for compensation of baseline shift in respiratory-gated radiation therapy.

Authors:  Eric W Pepin; Huanmei Wu; Hiroki Shirato
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

2.  Review of fast monte carlo codes for dose calculation in radiation therapy treatment planning.

Authors:  Keyvan Jabbari
Journal:  J Med Signals Sens       Date:  2011-01

3.  A margin-based analysis of the dosimetric impact of motion on step-and-shoot IMRT lung plans.

Authors:  Benjamin J Waghorn; Amish P Shah; Justin M Rineer; Katja M Langen; Sanford L Meeks
Journal:  Radiat Oncol       Date:  2014-02-05       Impact factor: 3.481

4.  Amplitude gating for a coached breathing approach in respiratory gated 10 MV flattening filter-free VMAT delivery.

Authors:  Francis Viel; Richard Lee; Ermias Gete; Cheryl Duzenli
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.