Literature DB >> 18446413

Digital radiography reject analysis: data collection methodology, results, and recommendations from an in-depth investigation at two hospitals.

David H Foos1, W James Sehnert, Bruce Reiner, Eliot L Siegel, Arthur Segal, David L Waldman.   

Abstract

Reject analysis was performed on 288,000 computed radiography (CR) image records collected from a university hospital (UH) and a large community hospital (CH). Each record contains image information, such as body part and view position, exposure level, technologist identifier, and--if the image was rejected--the reason for rejection. Extensive database filtering was required to ensure the integrity of the reject-rate calculations. The reject rate for CR across all departments and across all exam types was 4.4% at UH and 4.9% at CH. The most frequently occurring exam types with reject rates of 8% or greater were found to be common to both institutions (skull/facial bones, shoulder, hip, spines, in-department chest, pelvis). Positioning errors and anatomy cutoff were the most frequently occurring reasons for rejection, accounting for 45% of rejects at CH and 56% at UH. Improper exposure was the next most frequently occurring reject reason (14% of rejects at CH and 13% at UH), followed by patient motion (11% of rejects at CH and 7% at UH). Chest exams were the most frequently performed exam at both institutions (26% at UH and 45% at CH) with half captured in-department and half captured using portable x-ray equipment. A ninefold greater reject rate was found for in-department (9%) versus portable chest exams (1%). Problems identified with the integrity of the data used for reject analysis can be mitigated in the future by objectifying quality assurance (QA) procedures and by standardizing the nomenclature and definitions for QA deficiencies.

Entities:  

Mesh:

Year:  2008        PMID: 18446413      PMCID: PMC3043667          DOI: 10.1007/s10278-008-9112-5

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  2 in total

1.  Digital repeat analysis; setup and operation.

Authors:  J Nol; G Isouard; J Mirecki
Journal:  J Digit Imaging       Date:  2006-06       Impact factor: 4.056

2.  Is reject analysis necessary after converting to computed radiography?

Authors:  Rosemary Honea; Maria Elissa Blado; Yinlin Ma
Journal:  J Digit Imaging       Date:  2002-03-21       Impact factor: 4.056

  2 in total
  12 in total

1.  Investigation of the variability in the assessment of digital chest X-ray image quality.

Authors:  Jacquelyn S Whaley; Barry D Pressman; Jonathan R Wilson; Lionel Bravo; William J Sehnert; David H Foos
Journal:  J Digit Imaging       Date:  2013-04       Impact factor: 4.056

Review 2.  Development of a tool to aid the radiologic technologist using augmented reality and computer vision.

Authors:  Robert D MacDougall; Benoit Scherrer; Steven Don
Journal:  Pediatr Radiol       Date:  2017-09-02

3.  Managing repeat digital radiography images-a systematic approach and improvement.

Authors:  Wen-Sheng Tzeng; Kuang-Ming Kuo; Chung-Feng Liu; Huan-Chung Yao; Chin-Yu Chen; Huang-Wei Lin
Journal:  J Med Syst       Date:  2011-05-31       Impact factor: 4.460

4.  One year's results from a server-based system for performing reject analysis and exposure analysis in computed radiography.

Authors:  A Kyle Jones; Raimund Polman; Charles E Willis; S Jeff Shepard
Journal:  J Digit Imaging       Date:  2011-04       Impact factor: 4.056

5.  Evaluation of digital radiography practice using exposure index tracking.

Authors:  Alexander W Scott; Yifang Zhou; Janet Allahverdian; Jessica L Nute; Christina Lee
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

6.  Educational Module Intervention for Radiographers to Reduce Repetition Rate of Routine Digital Chest Radiography in Makkah Region of Saudi Arabia Tertiary Hospitals: Protocol of a Quasi-Experimental Study.

Authors:  Rosliza Abdul Manaf; Abdullah A Almalki; Muhamad Hanafiah Juni; Hayati Kadir Shahar; Noramaliza Mohd Noor; Abdelsafi Gabbad
Journal:  JMIR Res Protoc       Date:  2017-09-26

7.  Reject rate analysis in digital radiography: an Australian emergency imaging department case study.

Authors:  Samantha Atkinson; Michael Neep; Deborah Starkey
Journal:  J Med Radiat Sci       Date:  2019-07-18

8.  Digital radiograph rejection analysis during "Coronavirus disease 2019 (COVID-19) pandemic" in a tertiary care public sector hospital in Khyber Pakhtunkhwa Province of Pakistan.

Authors:  Amir Ali; Muhammad Yaseen
Journal:  Chin J Acad Radiol       Date:  2021-06-07

9.  Image rejects in general direct digital radiography.

Authors:  Bjørn Hofmann; Tine Blomberg Rosanowsky; Camilla Jensen; Kenneth Hong Ching Wah
Journal:  Acta Radiol Open       Date:  2015-10-08

10.  Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study.

Authors:  Mohd Yusmiaidil Putera Mohd Yusof; Nur Liyana Abdul Rahman; Amiza Aqiela Ahmad Asri; Noor Ilyani Othman; Ilham Wan Mokhtar
Journal:  Imaging Sci Dent       Date:  2017-12-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.