Literature DB >> 18442829

InfectCheck CRP barcode-style lateral flow assay for semi-quantitative detection of C-reactive protein in distinguishing between bacterial and viral infections.

Wingman Leung1, Cangel Puiyee Chan, Timothy H Rainer, Margaret Ip, George W H Cautherley, Reinhard Renneberg.   

Abstract

In the present study, we describe an InfectCheck barcode-style lateral flow assay for semi-quantitative detection of CRP in distinguishing between bacterial and viral infections. The severity of bacterial infection can be assessed by simply counting the number of red lines developed at the CRP test zone of the test device. If only one visible line appeared at the CRP test zone, it represents a low or mild inflammation with CRP levels <10 mg/L. Two and three visible lines mean moderate (>or=10-25 mg/L) and severe (>or=25-50 mg/L) inflammations respectively while four visible lines stand for a very severe inflammation (>or=50-100 mg/L). If the visible lines become faint and the intensity of the first line is weaker than that of the control line and may even disappear, this outcome corresponds to the stage of having super severe inflammation (>or=100 mg/L). A total of 500 patients admitted to hospital through the Accident and Emergency Unit at the Prince of Wales Hospital were examined. The InfectCheck CRP barcode-style rapid test gave a high sensitivity of 88.7% and a high negative predictive value of 93.8%. This result indicates that the rapid test is reliable to exclude non-infected patients. The calculated intra- and inter-assay coefficient of variation for the five CRP concentration ranges was both within 20.0%. It is a one-step whole blood rapid test without any sample pre-treatment and the result is available within 20 min. This user friendly diagnostic tool can allow self-testing by interested individuals without any expensive reading device.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18442829     DOI: 10.1016/j.jim.2008.03.009

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  14 in total

1.  A semi-quantitative rapid multi-range gradient lateral flow immunoassay for procalcitonin.

Authors:  Kseniya V Serebrennikova; Jeanne V Samsonova; Alexander P Osipov
Journal:  Mikrochim Acta       Date:  2019-06-11       Impact factor: 5.833

Review 2.  Progress in the development of paper-based diagnostics for low-resource point-of-care settings.

Authors:  Samantha Byrnes; Gregory Thiessen; Elain Fu
Journal:  Bioanalysis       Date:  2013-11       Impact factor: 2.681

3.  Recombinant antibody fragments allow repeated measurements of C-reactive protein with a quartz crystal microbalance immunosensor.

Authors:  Laila Al-Halabi; Anne Balck; Monika Michalzik; David Fröde; Stephanus Büttgenbach; Michael Hust; Thomas Schirrmann; Stefan Dübel
Journal:  MAbs       Date:  2012-12-06       Impact factor: 5.857

Review 4.  Enabling robust quantitative readout in an equipment-free model of device development.

Authors:  Elain Fu
Journal:  Analyst       Date:  2014-10-07       Impact factor: 4.616

5.  Counting-based microfluidic paper-based devices capable of analyzing submicroliter sample volumes.

Authors:  Md Almostasim Mahmud; Eric J M Blondeel; Brendan D MacDonald
Journal:  Biomicrofluidics       Date:  2020-01-10       Impact factor: 2.800

Review 6.  Point-of-care diagnostics to improve maternal and neonatal health in low-resource settings.

Authors:  Catherine E Majors; Chelsey A Smith; Mary E Natoli; Kathryn A Kundrod; Rebecca Richards-Kortum
Journal:  Lab Chip       Date:  2017-10-11       Impact factor: 6.799

Review 7.  Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays.

Authors:  Claudio Parolo; Amadeo Sena-Torralba; José Francisco Bergua; Enric Calucho; Celia Fuentes-Chust; Liming Hu; Lourdes Rivas; Ruslan Álvarez-Diduk; Emily P Nguyen; Stefano Cinti; Daniel Quesada-González; Arben Merkoçi
Journal:  Nat Protoc       Date:  2020-10-23       Impact factor: 13.491

8.  Optimization of an optical inspection system based on the Taguchi method for quantitative analysis of point-of-care testing.

Authors:  Chia-Hsien Yeh; Zi-Qi Zhao; Pi-Lan Shen; Yu-Cheng Lin
Journal:  Sensors (Basel)       Date:  2014-09-01       Impact factor: 3.576

Review 9.  Lateral flow assays.

Authors:  Katarzyna M Koczula; Andrea Gallotta
Journal:  Essays Biochem       Date:  2016-06-30       Impact factor: 8.000

10.  Instrumentation-Free Semiquantitative Immunoanalysis Using a Specially Patterned Lateral Flow Assay Device.

Authors:  Kyung Won Lee; Ye Chan Yu; Hyeong Jin Chun; Yo Han Jang; Yong Duk Han; Hyun C Yoon
Journal:  Biosensors (Basel)       Date:  2020-07-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.