Literature DB >> 18441412

Assessment of skin dose for breast chest wall radiotherapy as a function of bolus material.

Shu-Hui Hsu1, Peter L Roberson, Yu Chen, Robin B Marsh, Lori J Pierce, Jean M Moran.   

Abstract

Skin dose assessment for chest wall radiotherapy is important to ensure sufficient dose to the surface target volume without excessive skin reaction. This study quantified changes to the surface doses as a function of bolus material for conventional and intensity modulated radiation therapy (IMRT) tangential fields. Three types of bolus materials (2 mm solid, 2 mm fine mesh and 3.2 mm large mesh Aquaplast) were compared with Superflab. Surface dose measurements were performed using an Attix parallel plate chamber in a flat solid water phantom at 0 degrees , 45 degrees and 70 degrees incident angles. Over-response correction factors were applied to the Attix chamber results for different incident angles. Surface dose measurements on an anthropomorphic phantom were done using a thermoluminescent dosimeter extrapolation method. Dose characteristics of Superflab and solid Aquaplast were within 2% of solid water material. No significant differences (within 3%) in the surface dose were found between conventional and IMRT tangential techniques. The bolus effect was large for chest wall tangential radiotherapy, with up to an 82% increase using 2 mm fine mesh Aquaplast. The dosimetric effect of different Aquaplast materials has been quantified in this work. These materials can be used to create a custom bolus with potentially better reproducibility of placement.

Entities:  

Mesh:

Year:  2008        PMID: 18441412     DOI: 10.1088/0031-9155/53/10/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  21 in total

1.  Comparison of surface dose delivered by 7 MV-unflattened and 6 MV-flattened photon beams.

Authors:  Ashokkumar Sigamani; Arunai Nambiraj
Journal:  Rep Pract Oncol Radiother       Date:  2017-04-25

2.  Dosimetric Comparison of Superflab and Specially Prepared Bolus Materials Used in Radiotherapy Practice.

Authors:  Serhat Aras; İhsan Oğuz Tanzer; Türkan İkizceli
Journal:  Eur J Breast Health       Date:  2020-03-31

3.  Usefulness of Semi-cylindrical Beam Spoiler in Treatment of Early Glottic Cancer Using 6 MV Photon Beam.

Authors:  Seong Soo Shin; Sohyun Ahn; Seung-Hyup Baek; Jungwon Kwak; Jin Sung Kim; Woo Sang Ahn
Journal:  In Vivo       Date:  2022 Jan-Feb       Impact factor: 2.155

4.  Skin Surface Dose for Whole Breast Radiotherapy Using Personalized Breast Holder: Comparison with Various Radiotherapy Techniques and Clinical Experiences.

Authors:  Chiu-Ping Chen; Chi-Yeh Lin; Chia-Chun Kuo; Tung-Ho Chen; Shao-Chen Lin; Kuo-Hsiung Tseng; Hao-Wen Cheng; Hsing-Lung Chao; Sang-Hue Yen; Ruo-Yu Lin; Chen-Ju Feng; Long-Sheng Lu; Jeng-Fong Chiou; Shih-Ming Hsu
Journal:  Cancers (Basel)       Date:  2022-06-30       Impact factor: 6.575

5.  Assessment of skin dose in breast cancer radiotherapy: on-phantom measurement and Monte Carlo simulation.

Authors:  Mohammad Taghi Bahreyni Toossi; Nastaran Mohamadian; Mohammad Mohammadi; Mahdi Ghorbani; Mohsen Hassani; Benyamin Khajetash; Farideh Khorshidi; Courtney Knaup
Journal:  Rep Pract Oncol Radiother       Date:  2020-03-18

6.  On the Use of Optically Stimulated Luminescent Dosimeter for Surface Dose Measurement during Radiotherapy.

Authors:  Fasihah Hanum Yusof; Ngie Min Ung; Jeannie Hsiu Ding Wong; Wei Loong Jong; Vannyat Ath; Vincent Chee Ee Phua; Siew Ping Heng; Kwan Hoong Ng
Journal:  PLoS One       Date:  2015-06-08       Impact factor: 3.240

7.  In vivo skin dose measurement in breast conformal radiotherapy.

Authors:  Shokouhozaman Soleymanifard; Seyed Amir Aledavood; Atefeh Vejdani Noghreiyan; Mahdi Ghorbani; Farideh Jamali; David Davenport
Journal:  Contemp Oncol (Pozn)       Date:  2016-02-10

8.  Evaluation of skin dose associated with different frequencies of bolus applications in post-mastectomy three-dimensional conformal radiotherapy.

Authors:  Fundagul Andic; Yasemin Ors; Rima Davutoglu; Sule Baz Cifci; Emine Burcin Ispir; Mehmet Ertugrul Erturk
Journal:  J Exp Clin Cancer Res       Date:  2009-03-24

9.  An investigation of the depth dose in the build-up region, and surface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurements.

Authors:  Lukkana Apipunyasopon; Somyot Srisatit; Nakorn Phaisangittisakul
Journal:  J Radiat Res       Date:  2012-10-26       Impact factor: 2.724

10.  Surface dose measurements and comparison of unflattened and flattened photon beams.

Authors:  Ashokkumar Sigamani; Arunai Nambiraj; Girigesh Yadav; Ananda Giribabu; Karthikeyan Srinivasan; Venkadamanickam Gurusamy; Kothanda Raman; Kaviarasu Karunakaran; Rajesh Thiyagarajan
Journal:  J Med Phys       Date:  2016 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.