Literature DB >> 18437701

Decellularized, xenogeneic small-diameter arteries: transition from a muscular to an elastic phenotype in vivo.

Helga Bergmeister1, Roberto Plasenzotti, Ingrid Walter, Christian Plass, Fabienne Bastian, Erwin Rieder, Wolfgang Sipos, Alexandra Kaider, Udo Losert, Guenter Weigel.   

Abstract

Reports regarding the biocompatibility of xenogeneic, decellularized bioprosthetic implants differ between bioinertness and complete graft degradation. We investigated heparin-crosslinked and nonheparinized, xenogeneic vascular substitutes in a rat model. Porcine arteries (15 x 1.5 mm) were decellularized by multistep detergent and enzymatic techniques, which were followed by heparin-crosslinking in 50% of the implants. Prostheses were implanted into the abdominal aorta of 76 rats for 1 day and up to 6 months. Retrieved specimens were evaluated by histology, immunohistochemistry, laser scanning, and scanning electron microscopy. Graft patency did not differ between groups (97.3%). Heparinized grafts showed a statistically significant lower rate of aneurysm formation (p = 0.04 %). Implants revealed infiltration with granulocytes and macrophages up to 3 months. Recellularization with endothelial cells and myofibroblasts was detectable within 1 month. After 6 months elastin biosynthesis and complete graft remodeling toward an elastic vessel was evident. These results indicate that temporary inflammation does not interfere with long-term vascular remodeling. (c) 2008 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18437701     DOI: 10.1002/jbm.b.31074

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  5 in total

1.  Effect of treatment temperature on collagen structures of the decellularized carotid artery using high hydrostatic pressure.

Authors:  Jun Negishi; Seiichi Funamoto; Tsuyoshi Kimura; Kwangoo Nam; Tetsuya Higami; Akio Kishida
Journal:  J Artif Organs       Date:  2011-05-11       Impact factor: 1.731

2.  Mechanocompatible Polymer-Extracellular-Matrix Composites for Vascular Tissue Engineering.

Authors:  Bin Jiang; Rachel Suen; Jiao-Jing Wang; Zheng J Zhang; Jason A Wertheim; Guillermo A Ameer
Journal:  Adv Healthc Mater       Date:  2016-04-24       Impact factor: 9.933

Review 3.  Tissue engineering for the oncologic urinary bladder.

Authors:  Tomasz Drewa; Jan Adamowicz; Arun Sharma
Journal:  Nat Rev Urol       Date:  2012-08-21       Impact factor: 14.432

Review 4.  In Vivo Performance of Decellularized Vascular Grafts: A Review Article.

Authors:  Chih-Hsun Lin; Kai Hsia; Hsu Ma; Hsinyu Lee; Jen-Her Lu
Journal:  Int J Mol Sci       Date:  2018-07-19       Impact factor: 5.923

5.  The in vivo performance of small-caliber nanofibrous polyurethane vascular grafts.

Authors:  Zuo-jun Hu; Zi-lun Li; Ling-yu Hu; Wei He; Rui-ming Liu; Yuan-sen Qin; Shen-ming Wang
Journal:  BMC Cardiovasc Disord       Date:  2012-12-03       Impact factor: 2.298

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.