Results of a multicenter retrospective implantable cardioverter-defibrillator registry of pediatric and congenital heart disease patients.

Charles I Berul1, George F Van Hare, Naomi J Kertesz, Anne M Dubin, Frank Cecchin, Kathryn K Collins, Bryan C Cannon, Mark E Alexander, John K Triedman, Edward P Walsh, Richard A Friedman.   

Abstract

OBJECTIVES: We sought to determine the implications of implantable cardioverter-defibrillator (ICD) placement in children and patients with congenital heart disease (CHD).
BACKGROUND: There is increasing frequency of ICD use in pediatric and CHD patients. Until recently, prospective registry enrollment of ICD patients was not available, and children and CHD patients account for only a small percentage of ICD recipients. Therefore, we retrospectively obtained collaborative data from 4 pediatric centers, aiming to identify implant characteristics, shock frequency, and complications in this unique population.
METHODS: Databases from 4 centers were collated in a blinded fashion. Demographic information, implant electrical parameters, appropriate and inappropriate shock data, and complications were recorded for all implants from 1992 to 2004.
RESULTS: A total of 443 patients were included, with a median age of 16 years (range 0 to 54 years) and median weight of 61 kg (range 2 to 130 kg), with 69% having structural heart disease. The most common diagnoses were tetralogy of Fallot (19%) and hypertrophic cardiomyopathy (14%). Implant indication was primary prevention in 52%. Shock data were available on 409 patients, of whom 105 (26%) received appropriate shocks (mean 4 shocks/patient, range 1 to 29 shocks/patient). Inappropriate shocks occurred in 87 of 409 patients (21%), with a mean of 6 per patient (range 1 to 60), mainly attributable to lead failure (14%), sinus or atrial tachycardias (9%), and/or oversensing (4%).
CONCLUSIONS: Children and CHD ICD recipients have significant appropriate and inappropriate shock frequencies. Optimizing programming, medical management, and compliance may diminish inappropriate shocks. Despite concerns regarding generator recalls, lead failure remains the major cause of inappropriate shocks, complications, and system malfunction in children. Prospective assessment of ICD usage in this population may identify additional important factors in pediatric and CHD patients.

Entities:  

Mesh:

Year:  2008        PMID: 18436121     DOI: 10.1016/j.jacc.2008.01.033

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  51 in total

1.  Incidence of and risk factors for sudden cardiac death in children with dilated cardiomyopathy: a report from the Pediatric Cardiomyopathy Registry.

Authors:  Elfriede Pahl; Lynn A Sleeper; Charles E Canter; Daphne T Hsu; Minmin Lu; Steven A Webber; Steven D Colan; Paul F Kantor; Melanie D Everitt; Jeffrey A Towbin; John L Jefferies; Beth D Kaufman; James D Wilkinson; Steven E Lipshultz
Journal:  J Am Coll Cardiol       Date:  2012-02-07       Impact factor: 24.094

Review 2.  Initial experience of subcutaneous implantable cardioverter defibrillators in Singapore: a case series and review of the literature.

Authors:  Tien Siang Eric Lim; Boon Yew Tan; Kah Leng Ho; Chuh Yih Paul Lim; Wee Siong Teo; Chi-Keong Ching
Journal:  Singapore Med J       Date:  2015-10       Impact factor: 1.858

Review 3.  A contemporary assessment of the risk for sudden cardiac death in patients with congenital heart disease.

Authors:  Michael J Silka; Yaniv Bar-Cohen
Journal:  Pediatr Cardiol       Date:  2012-02-07       Impact factor: 1.655

Review 4.  Pregnancy in patients with implantable cardiac defibrillators.

Authors:  Geoffrey R Wong; Megan Ang; Jasveer Jayarajan; Fiona Walker; Pier D Lambiase
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2021-05-10

5.  Cardioverter-defibrillators for primary and secondary prevention in adults with tetralogy of fallot.

Authors:  Elyse Foster
Journal:  Curr Cardiol Rep       Date:  2009-07       Impact factor: 2.931

Review 6.  Arrhythmias in structural heart disease.

Authors:  H Sawyer Gillespie; Charles C H Lin; Jordan M Prutkin
Journal:  Curr Cardiol Rep       Date:  2014-08       Impact factor: 2.931

Review 7.  Approach to a Child with Congestive Heart Failure.

Authors:  Manojkumar Rohit; Sudhansu Budakoty
Journal:  Indian J Pediatr       Date:  2020-04       Impact factor: 1.967

8.  Pacing and Defibrillators in Complex Congenital Heart Disease.

Authors:  Henry Chubb; Mark O'Neill; Eric Rosenthal
Journal:  Arrhythm Electrophysiol Rev       Date:  2016-05

Review 9.  Sudden Cardiac Death in the Young.

Authors:  Michael Ackerman; Dianne L Atkins; John K Triedman
Journal:  Circulation       Date:  2016-03-08       Impact factor: 29.690

10.  Sudden death in pediatric populations.

Authors:  Mei-Hwan Wu
Journal:  Korean Circ J       Date:  2010-06-29       Impact factor: 3.243