| Literature DB >> 18435195 |
Masao Irie1, Yukinori Maruo, Goro Nishigawa, Goro Nishgawa, Kazuomi Suzuki, David C Watts.
Abstract
This in vitro study evaluated the effects of delayed versus immediate polishing to permit maturation of interfacial gap-formation around highly viscous conventional glass-ionomer cement (HV-GIC) in Class I restorations, together with determining the associated mechanical properties. Cavity preparations were made on the occlusal surfaces of premolars. Three HV-GICs (Fuji IX GP, GlasIonomer FX-II and Ketac Molar) and one conventional glass-ionomer cement (C-GIC, Fuji II, as a control) were studied, with specimen subgroups (n=10) for each property measured. After polishing, either immediately (six minutes) after setting or after 24 hours storage, the restored teeth were sectioned in a mesiodistal direction through the center of the model Class I restorations. The presence or absence of interfacial-gaps was measured at 1000x magnification at 14 points (each 0.5-mm apart) along the cavity restoration interface (n=10; total points measured per group = 140). Marginal gaps were similarly measured in Teflon molds as swelling data, together with shear-bond-strength to enamel and dentin, flexural strength and moduli. For three HV-GICs and one C-GIC, significant differences (p<0.05) in gap-incidence were observed between polishing immediately and after one-day storage. In the former case, 80-100 gaps were found. In the latter case, only 9-21 gaps were observed. For all materials, their shear-bond-strengths, flexural strength and moduli increased significantly after 24-hour storage.Mesh:
Substances:
Year: 2008 PMID: 18435195 DOI: 10.2341/07-75
Source DB: PubMed Journal: Oper Dent ISSN: 0361-7734 Impact factor: 2.440