Literature DB >> 18435195

Class I gap-formation in highly-viscous glass-ionomer restorations: delayed vs immediate polishing.

Masao Irie1, Yukinori Maruo, Goro Nishigawa, Goro Nishgawa, Kazuomi Suzuki, David C Watts.   

Abstract

This in vitro study evaluated the effects of delayed versus immediate polishing to permit maturation of interfacial gap-formation around highly viscous conventional glass-ionomer cement (HV-GIC) in Class I restorations, together with determining the associated mechanical properties. Cavity preparations were made on the occlusal surfaces of premolars. Three HV-GICs (Fuji IX GP, GlasIonomer FX-II and Ketac Molar) and one conventional glass-ionomer cement (C-GIC, Fuji II, as a control) were studied, with specimen subgroups (n=10) for each property measured. After polishing, either immediately (six minutes) after setting or after 24 hours storage, the restored teeth were sectioned in a mesiodistal direction through the center of the model Class I restorations. The presence or absence of interfacial-gaps was measured at 1000x magnification at 14 points (each 0.5-mm apart) along the cavity restoration interface (n=10; total points measured per group = 140). Marginal gaps were similarly measured in Teflon molds as swelling data, together with shear-bond-strength to enamel and dentin, flexural strength and moduli. For three HV-GICs and one C-GIC, significant differences (p<0.05) in gap-incidence were observed between polishing immediately and after one-day storage. In the former case, 80-100 gaps were found. In the latter case, only 9-21 gaps were observed. For all materials, their shear-bond-strengths, flexural strength and moduli increased significantly after 24-hour storage.

Mesh:

Substances:

Year:  2008        PMID: 18435195     DOI: 10.2341/07-75

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  3 in total

1.  An evaluation of microleakage of various glass ionomer based restorative materials in deciduous and permanent teeth: An in vitro study.

Authors:  Teena Singla; I K Pandit; Nikhil Srivastava; Neeraj Gugnani; Monika Gupta
Journal:  Saudi Dent J       Date:  2011-11-16

2.  The effect of mechanical load cycling and polishing time on microleakage of class V glass-ionomer and composite restorations: A scanning electron microscopy evaluation.

Authors:  Mansoreh Mirzaie; Esmail Yasini; Hamid Kermanshah; Baharan Ranjbar Omidi
Journal:  Dent Res J (Isfahan)       Date:  2014-01

3.  The effect of short polyethylene fiber with different weight percentages on diametral tensile strength of conventional and resin modified glass ionomer cements.

Authors:  Farahnaz Sharafeddin; Seyed-Ali Ghaboos; Zahra Jowkar
Journal:  J Clin Exp Dent       Date:  2017-03-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.