Literature DB >> 18433612

Reconstruction of standard 12-lead electrocardiograms from 12-lead electrocardiograms recorded with the Mason-Likar electrode configuration.

Sum-Che Man1, Arie C Maan, Eunhyo Kim, Harmen H M Draisma, Martin J Schalij, Ernst E van der Wall, Cees A Swenne.   

Abstract

Electrocardiograms (ECGs) made with Mason-Likar electrode configuration (ML-ECGs) show well-known differences from standard 12-lead ECGs (Std-ECGs). We recorded, simultaneously, Std-ECGs and ML-ECGs in 180 subjects. Using these ECGs, 8 x 8 individual and general conversion matrices were created by linear regression, and standard ECGs were reconstructed from ML-ECGs using these matrices. The performance of the matrices was assessed by the root mean square differences between the original Std-ECGs and the reconstructed standard ECGs, by the differences in major ECG parameters, and by comparison of computer-generated diagnostic statements. As a result, we conclude that, based on the root mean square differences, reconstructions with 8 x 8 individual matrices perform significantly better than reconstructions with the group matrix and perform equally well with respect to the calculation of major electrocardiographic parameters, which gives an improved reliability of the QRS frontal axis and the maximal QRS and T amplitudes. Both types of matrices were able to reverse the underdiagnosis of inferior myocardial infarctions and the erroneous statements about the QRS frontal axis that arose in the ECGs that were made by using the Mason-Likar electrode positions.

Entities:  

Mesh:

Year:  2008        PMID: 18433612     DOI: 10.1016/j.jelectrocard.2008.01.009

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  4 in total

Review 1.  Technical mistakes during the acquisition of the electrocardiogram.

Authors:  Javier García-Niebla; Pablo Llontop-García; Juan Ignacio Valle-Racero; Guillem Serra-Autonell; Velislav N Batchvarov; Antonio Bayés de Luna
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-10       Impact factor: 1.468

Review 2.  12-lead Holter electrocardiography. Review of the literature and clinical application update.

Authors:  Li Su; Stefan Borov; Bernhard Zrenner
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-06-19

Review 3.  The spatial QRS-T angle: implications in clinical practice.

Authors:  Christina Voulgari; Stamatina Pagoni; Solomon Tesfaye; Nicholas Tentolouris
Journal:  Curr Cardiol Rev       Date:  2013-08

4.  An initial exploration of subtraction electrocardiography to detect myocardial ischemia in the prehospital setting.

Authors:  Cornelia Cato Ter Haar; Ron J G Peters; Jan Bosch; Agnese Sbrollini; Sophia Gripenstedt; Rob Adams; Eduard Bleijenberg; Charles J H J Kirchhof; Reza Alizadeh Dehnavi; Laura Burattini; Robbert J de Winter; Peter W Macfarlane; Pieter G Postema; Sumche Man; Roderick W C Scherptong; Martin J Schalij; Arie C Maan; Cees A Swenne
Journal:  Ann Noninvasive Electrocardiol       Date:  2019-11-10       Impact factor: 1.468

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.