Literature DB >> 18431115

Hemodynamic changes associated with spinal anesthesia for cesarean delivery in severe preeclampsia.

Robert A Dyer1, Jenna L Piercy, Anthony R Reed, Carl J Lombard, Leann K Schoeman, Michael F James.   

Abstract

BACKGROUND: Hemodynamic responses to spinal anesthesia (SA) for cesarean delivery in patients with severe preeclampsia are poorly understood. This study used a beat-by-beat monitor of cardiac output (CO) to characterize the response to SA. The hypothesis was that CO would decrease from baseline values by less than 20%.
METHODS: Fifteen patients with severe preeclampsia consented to an observational study. The monitor employed used pulse wave form analysis to estimate nominal stroke volume. Calibration was by lithium dilution. CO and systemic vascular resistance were derived from the measured stroke volume, heart rate, and mean arterial pressure. In addition, the hemodynamic effects of phenylephrine, the response to delivery and oxytocin, and hemodynamics during recovery from SA were recorded. Hemodynamic values were averaged for defined time intervals before, during, and after SA.
RESULTS: Cardiac output remained stable from induction of SA until the time of request for analgesia. Mean arterial pressure and systemic vascular resistance decreased significantly from the time of adoption of the supine position until the end of surgery. After oxytocin administration, systemic vascular resistance decreased and heart rate and CO increased. Phenylephrine, 50 mug, increased mean arterial pressure to above target values and did not significantly change CO. At the time of recovery from SA, there were no clinically relevant changes from baseline hemodynamic values.
CONCLUSIONS: Spinal anesthesia in severe preeclampsia was associated with clinically insignificant changes in CO. Phenylephrine restored mean arterial pressure but did not increase maternal CO. Oxytocin caused transient marked hypotension, tachycardia, and increases in CO.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18431115     DOI: 10.1097/01.anes.0000311153.84687.c7

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  15 in total

1.  [New aspects of obstetric anesthesia].

Authors:  T Girard; S Brugger; I Hösli
Journal:  Anaesthesist       Date:  2013-12       Impact factor: 1.041

2.  Analgesia in Obstetrics.

Authors:  M Heesen; M Veeser
Journal:  Geburtshilfe Frauenheilkd       Date:  2012-07       Impact factor: 2.915

3.  Clinical evaluation of the flotrac/Vigileo system for continuous cardiac output monitoring in patients undergoing regional anesthesia for elective cesarean section: a pilot study.

Authors:  José Otavio Costa Auler; Marcelo L A Torres; Mônica M Cardoso; Thais C Tebaldi; André P Schmidt; Mario M Kondo; Marcelo Zugaib
Journal:  Clinics (Sao Paulo)       Date:  2010-06       Impact factor: 2.365

4.  Burden of proof.

Authors:  Richard M Smiley
Journal:  Anesthesiology       Date:  2009-09       Impact factor: 7.892

5.  Cardiac output in idiopathic normal pressure hydrocephalus: association with arterial blood pressure and intracranial pressure wave amplitudes and outcome of shunt surgery.

Authors:  Per K Eide
Journal:  Fluids Barriers CNS       Date:  2011-02-04

6.  Goal-directed haemodynamic therapy during elective total hip arthroplasty under regional anaesthesia.

Authors:  Maurizio Cecconi; Nicola Fasano; Nicola Langiano; Michele Divella; Maria G Costa; Andrew Rhodes; Giorgio Della Rocca
Journal:  Crit Care       Date:  2011-05-30       Impact factor: 9.097

7.  Subarachnoid block for caesarean section in severe preeclampsia.

Authors:  Sujata Chaudhary; Rashmi Salhotra
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2011-04

8.  Determination of the 90% Effective Dose of Phenylephrine Boluses to Treat Spinal Anesthesia-Induced Hypotension in Patients with Severe Preeclampsia during Cesarean Delivery: A Pilot Study.

Authors:  Jin-Ping Liu; Zheng-Bin Pan; Miao Zhu; Guo-Wei Zhu; Da-Bing Song; Xin-Zhong Chen; Xiao-Wei Qian
Journal:  Drug Des Devel Ther       Date:  2021-09-07       Impact factor: 4.162

9.  Vasopressors and tight control of maternal blood pressure during cesarean delivery: A rocky alliance.

Authors:  Sunanda Gupta
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-01

Review 10.  Regional anesthesia in patients with pregnancy induced hypertension.

Authors:  Saravanan P Ankichetty; Ki Jinn Chin; Vincent W Chan; Raj Sahajanandan; Hungling Tan; Anju Grewal; Anahi Perlas
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.