Hemostatic properties of four devices for partial nephrectomy: a comparative ex vivo study.

Patrick Honeck1, Gunnar Wendt-Nordahl, Christian Bolenz, Tina Peters, Christel Weiss, Peter Alken, Maurice-Stephan Michel, Axel Häcker.   

Abstract

PURPOSE: Laparoscopic partial nephrectomy (LPN) is a common minimally-invasive treatment modality for renal tumors, and achieving hemostasis during excision is a major challenge. The aim of our study was to investigate the hemostatic potential of four different devices for realizing this under standardized conditions.
MATERIALS AND METHODS: LPN was performed on a standardized model of blood-perfused ex-vivo porcine kidneys. Each of the four devices (Greenlight KTP laser, Habib Sealer, LigaSure, and SonoSurg) as well as a scalpel (for comparison) were used to perform 10 excisions with the renal artery and vein clamped, and another 10 were performed with no clamping. Treatment time (TT), blood loss (BL), and the ease of handling of the device were measured and histologic examination of the margins was carried out.
RESULTS: In general, TT was faster and there was less BL with clamping than without in all cases. TT was shortest for the KTP laser (6.07+/-1.2 minutes; P<0.0001), followed by the LigaSure (8.78+/-0.42 minutes), the SonoSurg (15.9+/-1.28 minutes), and the Habib (21.7+/-3.4 min). The SonoSurg showed a significantly higher BL without clamping (66+/-6 ml, p<0.0001) but there were no significant differences between the other devices. With clamping, BL four all four devices was comparable (13+/-2 ml) and without statistical significance (p=0.5). TT was shortest for the KTP laser (3.27+/-0.55 min, p<0.0001) followed by the LigaSure (6.47+/-0.38 s), the SonoSurg (8.35+/-3 min) and the Habib (9.71+/-1.18 minutes). The excised surface was completely coagulated for all of the devices except for the SonoSurg.
CONCLUSION: Our ex-vivo study suggests that hemostatic potential and the coagulative effect of all four devices is inadequate. Furthermore, none of the devices produced clean and sharp resection margins, which is a prerequisite for negative surgical margins.

Entities:  

Mesh:

Year:  2008        PMID: 18429683     DOI: 10.1089/end.2007.0236

Source DB:  PubMed          Journal:  J Endourol        ISSN: 0892-7790            Impact factor:   2.942


  4 in total

1.  Use of the LigaSure device and the Stapler for closure of the small bowel: a comparative ex vivo study.

Authors:  Mario Santini; Alfonso Fiorelli; Gaetana Messina; Paolo Laperuta; Antonio Mazzella; Marina Accardo
Journal:  Surg Today       Date:  2012-09-15       Impact factor: 2.549

2.  Comparison between a 1.92-μm fiber laser and a standard HF-dissection device for nephron-sparing kidney resection in a porcine in vivo study.

Authors:  Dirk Theisen-Kunde; Sönke Tedsen; Christian Doehn; Dieter Jocham; Ingo Kausch von Schmeling
Journal:  Lasers Med Sci       Date:  2011-01-18       Impact factor: 3.161

3.  Laparoscopic partial nephrectomy: Technical considerations and an update.

Authors:  Jose L Dominguez-Escrig; Nikhil Vasdev; Anna O'Riordon; Naeem Soomro
Journal:  J Minim Access Surg       Date:  2011-10       Impact factor: 1.407

4.  Laparoscopic partial nephrectomy using a flexible CO2 laser fiber.

Authors:  Ofer N Gofrit; Abed Khalaileh; Oleg Ponomarenko; Mahmoud Abu-Gazala; Reuven M Lewinsky; Ram Elazary; Noam Shussman; Arieh Shalhav; Yoav Mintz
Journal:  JSLS       Date:  2012 Oct-Dec       Impact factor: 2.172

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.