Literature DB >> 18427808

Malaria detection with the Sysmex XE-2100 hematology analyzer using pseudoeosinophilia and abnormal WBC scattergram.

Hee Jin Huh1, Gwi Young Oh, Jung Won Huh, Seok Lae Chae.   

Abstract

Recent investigation using the Sysmex XE-2100 hematology analyzer (Sysmex Corporation, Japan) has demonstrated erroneously high eosinophil counts and abnormal white blood cell (WBC) scattergrams in malaria cases. This study was conducted to assess the diagnostic efficiency of the Sysmex XE-2100 analyzer for malaria. One hundred forty-four patients initially diagnosed with Plasmodium vivax infection, 319 patients with febrile illness, and 24 patients who underwent malaria treatment were analyzed. Atypical features on Sysmex XE-2100 analyzer were categorized as pseudoeosinophilia (a gap of more than 5% in eosinophil counts between the Sysmex XE-2100 analyzer and microscopic examination) and abnormal WBC scattergram. Pseudoeosinophilia or abnormal WBC scattergram were detected in 100 of 144 malaria-positive samples (sensitivity 69.4%, specificity 100%). The samples with pseudoeosinophilia or abnormal WBC scattergrams showed significantly higher parasite counts than the samples without pseudoeosinophilia or an abnormal WBC scattergram (P<0.05). All 24 samples from patients for whom the malaria smear was repeated after malaria treatment was initiated showed a normalized eosinophil count and a normal WBC histogram. In conclusion, attention to differential count and WBC scattergrams provided by the Sysmex XE-2100 would be a valuable tool in malaria detection.

Entities:  

Mesh:

Year:  2008        PMID: 18427808     DOI: 10.1007/s00277-008-0486-8

Source DB:  PubMed          Journal:  Ann Hematol        ISSN: 0939-5555            Impact factor:   3.673


  11 in total

1.  Design of malaria diagnostic criteria for the Sysmex XE-2100 hematology analyzer.

Authors:  Germán Campuzano-Zuluaga; Gonzalo Alvarez-Sánchez; Gloria Elcy Escobar-Gallo; Luz Marina Valencia-Zuluaga; Alexandra Marcela Ríos-Orrego; Adriana Pabón-Vidal; Andrés Felipe Miranda-Arboleda; Silvia Blair-Trujillo; Germán Campuzano-Maya
Journal:  Am J Trop Med Hyg       Date:  2010-03       Impact factor: 2.345

2.  Automated detection of malaria-associated pseudoeosinophilia and abnormal WBC scattergram by the Sysmex XE-2100 hematology analyzer: a clinical study with 1,801 patients and real-time quantitative PCR analysis in vivax malaria-endemic area.

Authors:  Jong-Ha Yoo; Jaewoo Song; Kyung-A Lee; Young-Kyu Sun; Young-Ah Kim; Tae Sung Park; Jong Rak Choi
Journal:  Am J Trop Med Hyg       Date:  2010-03       Impact factor: 2.345

3.  Detection of intracellular parasites by use of the CellaVision DM96 analyzer during routine screening of peripheral blood smears.

Authors:  Lori D Racsa; Rita M Gander; Paul M Southern; Erin McElvania TeKippe; Christopher Doern; Hung S Luu
Journal:  J Clin Microbiol       Date:  2014-11-05       Impact factor: 5.948

4.  Malaria Diagnosis Using Automated Analysers: A Boon for Hematopathologists in Endemic Areas.

Authors:  Aminder Singh; Vikram Narang; Neena Sood; Bhavna Garg; Vikram Kumar Gupta
Journal:  J Clin Diagn Res       Date:  2015-10-01

5.  Efficacy and safety of artemisinin-naphthoquine versus dihydroartemisinin-piperaquine in adult patients with uncomplicated malaria: a multi-centre study in Indonesia.

Authors:  Emiliana Tjitra; Armedy R Hasugian; Hadjar Siswantoro; Budi Prasetyorini; Riyanti Ekowatiningsih; Endah A Yusnita; Telly Purnamasari; Srilaning Driyah; Ervi Salwati; Eni Yuwarni; Lidwina Januar; Joseph Labora; Bambang Wijayanto; Fajar Amansyah; Tersila A D Dedang; Asep Purnama
Journal:  Malar J       Date:  2012-06-14       Impact factor: 2.979

Review 6.  Automated haematology analysis to diagnose malaria.

Authors:  Germán Campuzano-Zuluaga; Thomas Hänscheid; Martin P Grobusch
Journal:  Malar J       Date:  2010-11-30       Impact factor: 2.979

7.  Automated Hematology Analyzers in Diagnosis of Plasmodium vivax Malaria: an Adjunct to Conventional Microscopy.

Authors:  Kolakkadan Hasaf Mubeen; Clement Wilfred Devadoss; Rau Aarathi Rangan; Monnappa Gitanjali; Shetty Prasanna; Vp Sunitha
Journal:  Mediterr J Hematol Infect Dis       Date:  2014-06-01       Impact factor: 2.576

8.  Laboratory Diagnosis of Malaria: Comparison of Manual and Automated Diagnostic Tests.

Authors:  Samina Naz Mukry; Madiha Saud; Gul Sufaida; Kashif Shaikh; Arshi Naz; Tahir Sultan Shamsi
Journal:  Can J Infect Dis Med Microbiol       Date:  2017-04-05       Impact factor: 2.471

9.  The XN-30 hematology analyzer for rapid sensitive detection of malaria: a diagnostic accuracy study.

Authors:  Annelies Post; Berenger Kaboré; Isaie J Reuling; Joel Bognini; Wouter van der Heijden; Salou Diallo; Palpouguini Lompo; Basile Kam; Natacha Herssens; Kjerstin Lanke; Teun Bousema; Robert W Sauerwein; Halidou Tinto; Jan Jacobs; Quirijn de Mast; Andre J van der Ven
Journal:  BMC Med       Date:  2019-05-31       Impact factor: 8.775

10.  Incidental Identification of Plasmodium vivax During Routine Complete Blood Count Analysis Using the UniCel DxH 800.

Authors:  Soyoung Shin; Sun Hee Park; Joonhong Park
Journal:  Ann Lab Med       Date:  2018-03       Impact factor: 3.464

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.