Literature DB >> 18425757

A new insight into suction and dilution effects in capillary electrophoresis coupled to mass spectrometry via an electrospray ionization interface. Part I-Suction effect.

Meriem Mokaddem1, Pierre Gareil, Jamel-Eddine Belgaied, Anne Varenne.   

Abstract

The hyphenation of CE with MS is nowadays accepted as a powerful analytical approach. Employing ESI, the most common interface, one challenge is to provide quantitative information, which is quite a difficult task, as it is linked, among other factors, to suction and dilution effects. In the coaxial ESI configuration, the suction effect has been presented in literature as stemming from nebulizing gas (NG) flow rate and drying gas temperature. But as this interface consists in three concentric capillaries, allowing for BGE, sheath liquid (SL) and NG mixing, it is demonstrated herein that other parameters are also involved in this suction effect: the CE capillary protrusion from the interface needle, SL flow rate, and overall BGE flow rate and velocity profile. Whereas NG flow rate is the parameter affecting suction to a greater extent, separation capillary protruding length, SL, and overall BGE flow rate have a significant additional impact on this phenomenon. It is shown that SL flow rate can affect suction differently according to the NG velocity, which may be explained by modification of the Taylor cone geometry. Furthermore, it appears that suction effect is noticeably favored by a parabolic velocity profile of the BGE, again probably due to the Taylor cone shape modification. Finally, the temperature gradient created by the contact between the heated NG and the separation capillary enhances this effect.

Entities:  

Mesh:

Year:  2008        PMID: 18425757     DOI: 10.1002/elps.200700880

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

1.  Development of an enantioselective assay for simultaneous separation of venlafaxine and O-desmethylvenlafaxine by micellar electrokinetic chromatography-tandem mass spectrometry: Application to the analysis of drug-drug interaction.

Authors:  Yijin Liu; Michael Jann; Chad Vandenberg; Chin B Eap; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2015-10-03       Impact factor: 4.759

2.  Multivariate approach for the enantioselective analysis in micellar electrokinetic chromatography-mass spectrometry. I. Simultaneous optimization of binaphthyl derivatives in negative ion mode.

Authors:  Jun He; Shahab A Shamsi
Journal:  J Chromatogr A       Date:  2008-12-06       Impact factor: 4.759

3.  Separation and characterization of nitrated variants of the major birch pollen allergen by CZE-ESI-μTOF MS.

Authors:  Sergey Gusenkov; Chloé Ackaert; Hanno Stutz
Journal:  Electrophoresis       Date:  2013-08-21       Impact factor: 3.535

4.  A Non-Targeted Capillary Electrophoresis-Mass Spectrometry Strategy to Study Metabolic Differences in an In vitro Model of High-Glucose Induced Changes in Human Proximal Tubular HK-2 Cells.

Authors:  Samuel Bernardo-Bermejo; Elena Sánchez-López; María Castro-Puyana; Selma Benito-Martínez; Francisco Javier Lucio-Cazaña; María Luisa Marina
Journal:  Molecules       Date:  2020-01-24       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.