Image quality in partially erased DenOptix storage phosphor plates.

Sérgio Lúcio Pereira de Castro Lopes1, Adriana Dibo da Cruz, Rívea Inês Ferreira, Frab Norberto Bóscolo, Solange Maria de Almeida.   

Abstract

This study aimed at investigating the effect of the partial erasing of DenOptix system storage phosphor plates on the image quality of digital radiographs. Standardized digital radiographs were acquired of a phantom mandible, using size 2 intraoral DenOptix storage phosphor plates (n = 10). Subsequently, the active areas of the plates were placed in a viewing box with a constant light intensity of 1,700 lux for 130 seconds to achieve complete erasing (control plate), as well as for 0, 5, 10, 15, 20, 25, 34, 66, and 98 seconds, to compose the experimental group of partially erased plates. The same exposure settings were repeated using the control and experimental plates, which were scanned at a resolution of 300 dpi. Five radiologists independently examined the pairs of digital radiographs obtained with the control and partially erased plates, in random order, and indicated the best image for oral diagnosis. Cochran-Mantel-Haenszels chi-square test, at a significance level of 5%, was used to compare the percentages of superior quality images in each combination of control and partially erased plates, subjectively assessed. No significant differences were found between radiographic images acquired with control and partially erased plates, except for the combination of 0 second (30%) versus 130 seconds (70%), p = 0.0047. It can be concluded that, under adequate light intensity conditions, erasing intraoral DenOptix storage phosphor plates may require time intervals of as little as 5 seconds.

Entities:  

Mesh:

Year:  2008        PMID: 18425250     DOI: 10.1590/s1806-83242008000100014

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  5 in total

1.  The effect of delayed scanning of storage phosphor plates on occlusal caries detection.

Authors:  E Sogur; B G Baksi; A Mert
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

2.  Effect of alternative photostimulable phosphor plates erasing times on subjective digital image quality.

Authors:  D P Melo; A Dos Anjos Pontual; S M de Almeida; P S F Campos; M C Alves; G M Tosoni
Journal:  Dentomaxillofac Radiol       Date:  2010-01       Impact factor: 2.419

3.  Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

Authors:  Daniela Pita De Melo; Adriana Dibo Cruz; Saulo Leonardo Sousa Melo; Julyanna Filgueiras GonçAlves De Farias; Francisco Haiter-Neto; Solange Maria De Almeida
Journal:  J Clin Diagn Res       Date:  2015-04-01

4.  Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates.

Authors:  Amir Eskandarloo; Arman Yousefi; Setareh Soheili; Karim Ghazikhanloo; Payam Amini; Haniyeh Mohammadpoor
Journal:  Open Dent J       Date:  2017-12-29

5.  Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions.

Authors:  Raquel Venâncio Fernandes Dantas; Hugo Ramalho Sarmento; Rosângela Marques Duarte; Sônia Saeger Meireles Monte Raso; Ana Karina Maciel de Andrade; Maria Luiza Dos Anjos-Pontual
Journal:  Imaging Sci Dent       Date:  2013-09-23
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.