Mechanical stability of structured bone grafts from the anterior iliac crest.

Dominik Parsch1, Thomas Breitwieser, Steffen J Breusch.   

Abstract

BACKGROUND: The anterior part of the iliac crest is frequently used as a donor site for autogenous bone grafts. Depending on the clinical scenario, the grafts are exposed to compression and shear stresses. Insufficient stability of a bone graft can lead to the collapse of a reconstruction. The object of this study was to quantify the influence of surgery-related parameters like the bony composition (cancellous, unicortical and bicortical), the donor site and the angle of removal on the failure load of the bone plugs (shearing and compression tests).
METHODS: A total of 137 bone cylinders varying in bony composition and in their angles to the trajectories in the anterior iliac crest were taken from 48 human hemipelvises with diamond hollow cutters. The failure load was measured in a standardized manner, each bone plug being subjected to two shear tests and three compression tests. Possible differences between groups were evaluated using analysis of covariance techniques with BMI, bone density and cortical thickness as covariates. The statistical significance level was set to 5% (P<0.05), no adjustment for multiple comparisons was done due to the descriptive nature of the study.
FINDINGS: Bicortical bone plugs were more resistant than unicortical plugs to both compression and shear stress, and both were more stable than cancellous bone plugs (P<0.05). On average, the compression failure load was about twice as high as the corresponding failure load with shearing tests: the factor was approximately 1.5 for cancellous, approximately 2 for unicortical and approximately 3 for bicortical bone plugs. We could not find a significant effect of the precise donor site and the angle of removal (parallel or perpendicular to the crista) on the mechanical stability of cancellous bone plugs.
INTERPRETATION: Surgeons should rather focus on the cancellous or cortical composition of the graft than location of the harvesting site or drilling angle in order to obtain a useful bone plug from the iliac crest.

Entities:  

Mesh:

Year:  2008        PMID: 18423953     DOI: 10.1016/j.clinbiomech.2008.02.014

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  4 in total

1.  Risk of graft fracture after dorso-ventral thoraco-lumbar spondylodesis: is there a correlation with graft size?

Authors:  David Kubosch; Stefan Milz; Christian Lohrmann; Karsten Schwieger; Lukas Konstantinidis; Christoph M Sprecher; Norbert P Südkamp; Peter C Strohm
Journal:  Eur Spine J       Date:  2011-07-12       Impact factor: 3.134

2.  Standardizing compression testing for measuring the stiffness of human bone.

Authors:  S Zhao; M Arnold; S Ma; R L Abel; J P Cobb; U Hansen; O Boughton
Journal:  Bone Joint Res       Date:  2018-09-15       Impact factor: 5.853

3.  Enhanced Bone Regeneration in Variable-Type Biphasic Ceramic Phosphate Scaffolds Using rhBMP-2.

Authors:  Ho-Kyung Lim; Ik-Jae Kwon; Sung-Woon On; Seok-Jin Hong; Byoung-Eun Yang; Soung-Min Kim; Jong-Ho Lee; Soo-Hwan Byun
Journal:  Int J Mol Sci       Date:  2021-10-25       Impact factor: 5.923

4.  Bone regeneration in ceramic scaffolds with variable concentrations of PDRN and rhBMP-2.

Authors:  Ho-Kyung Lim; Yeh-Jin Kwon; Seok-Jin Hong; Hyo-Geun Choi; Sung-Min Chung; Byoung-Eun Yang; Jong-Ho Lee; Soo-Hwan Byun
Journal:  Sci Rep       Date:  2021-06-01       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.