Literature DB >> 18422989

Topical application of statin affects bone healing around implants.

Yasuko Moriyama1, Yasunori Ayukawa, Yoichiro Ogino, Ikiru Atsuta, Kiyoshi Koyano.   

Abstract

OBJECTIVES: 3-hydroxy-3-methylglutaryl coenzyme A reductase inhibitors (statins) are widely used for hyperlipidemia. Recent studies demonstrate that statins stimulate bone morphogenetic protein-2 expression and lead to bone formation. The aim of this study was to evaluate whether the topical application of statin enhances the osteogenesis around a titanium implant.
MATERIALS AND METHODS: Ten-week-old female rats received pure titanium rods in both tibiae with or without fluvastatin. Propylene glycol alginate (PGA) was used as a carrier. The rats were divided into five groups: implant-only group, implant with PGA group, low-dose group [implant+PGA containing 3 microg of fluvastatin (FS)], medium-dose group (15 microg of FS), and high-dose group (75 microg of FS). The animals were sacrificed at 1 and 2 weeks after implantation. Peri-implant bone formation was assessed by histomorphometric procedures, i.e., measuring the bone-implant contact (BIC) and peri-implant bone volume (BV). A mechanical push-out test was also performed to evaluate the implant fixation strength. Statistical differences among the groups were determined by ANOVA and P < 0.05 was considered significant.
RESULTS: At week 1, there was no significant difference in BIC among the groups, however, BV and the push-out strength were significantly higher in the high-dose group than in the implant-only group. At week 2, BIC and BV had significantly increased in the high-dose group in comparison with the non-statin groups. The fluvastatin-treatment group showed a significant increase in push-out strength compared with the non-statin groups.
CONCLUSION: Our histomorphometrical and mechanical evaluations revealed the positive effect of topically applied fluvastatin on the bone around the implant.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18422989     DOI: 10.1111/j.1600-0501.2007.01508.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  12 in total

Review 1.  The effects of statins on dental and oral health: a review of preclinical and clinical studies.

Authors:  Shabnam Tahamtan; Farinaz Shirban; Mohammad Bagherniya; Thomas P Johnston; Amirhossein Sahebkar
Journal:  J Transl Med       Date:  2020-04-06       Impact factor: 5.531

2.  Effect of Timing and Duration of Statin Exposure on Risk of Hip or Knee Revision Arthroplasty: A Population-based Cohort Study.

Authors:  Michael J Cook; Antony K Sorial; Mark Lunt; Tim N Board; Terence W O'Neill
Journal:  J Rheumatol       Date:  2019-03-15       Impact factor: 5.346

3.  The initial inflammatory response to bioactive implants is characterized by NETosis.

Authors:  Ljubomir Vitkov; Wolf-Dietrich Krautgartner; Astrid Obermayer; Walter Stoiber; Matthias Hannig; Michaela Klappacher; Dominik Hartl
Journal:  PLoS One       Date:  2015-03-23       Impact factor: 3.240

4.  Simvastatin Effects on Dental Socket Quality: A Comparative Study.

Authors:  Mehdi Sezavar; Behnam Bohlouli; Sareh Farhadi; Shiva Tabatabaee; Reza Latifi
Journal:  Contemp Clin Dent       Date:  2018 Jan-Mar

Review 5.  Statins, bone biology and revision arthroplasty: review of clinical and experimental evidence.

Authors:  Antony K Sorial; Sami A Anjum; Michael J Cook; Tim N Board; Terence W O'Neill
Journal:  Ther Adv Musculoskelet Dis       Date:  2020-12-16       Impact factor: 5.346

6.  Influence of statins locally applied from orthopedic implants on osseous integration.

Authors:  Stephan Pauly; David A Back; Kathrin Kaeppler; Norbert P Haas; Gerhard Schmidmaier; Britt Wildemann
Journal:  BMC Musculoskelet Disord       Date:  2012-10-26       Impact factor: 2.362

7.  The pleotropic role of statins: Could it be the imminent host modulation agent in periodontics?

Authors:  Harpreet Singh Grover; Shailly Luthra; Shruti Maroo; Niteeka Maroo
Journal:  Dent Res J (Isfahan)       Date:  2013-03

8.  Improved anchorage of Ti6Al4V orthopaedic bone implants through oligonucleotide mediated immobilization of BMP-2 in osteoporotic rats.

Authors:  Julia V Wölfle; Jörg Fiedler; Lutz Dürselen; Judith Reichert; Dieter Scharnweber; Anne Förster; Bernd Schwenzer; Heiko Reichel; Anita Ignatius; Rolf E Brenner
Journal:  PLoS One       Date:  2014-01-21       Impact factor: 3.240

9.  Bone marrow stromal cells from low-turnover osteoporotic mouse model are less sensitive to the osteogenic effects of fluvastatin.

Authors:  Yukari Oda; Hodaka Sasaki; Tadashi Miura; Takuya Takanashi; Yoshitaka Furuya; Masao Yoshinari; Yasutomo Yajima
Journal:  PLoS One       Date:  2018-08-24       Impact factor: 3.240

10.  Comparison the effects of chitosan and hyaluronic acid-based thermally sensitive hydrogels containing rosuvastatin on human osteoblast-like MG-63 cells.

Authors:  Vajihe Akbari; Mahboubeh Rezazadeh; Zahra Ebrahimi
Journal:  Res Pharm Sci       Date:  2020-02-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.