Relationship between dental implant stability determined by resonance frequency analysis measurements and peri-implant vertical defects: an in vitro study.

T F Tözüm1, I Turkyilmaz, E A McGlumphy.   

Abstract

Resonance frequency (RF) analysis is a non-invasive and objective technique developed for implantology, where it measures the stability of the implant in the bone socket. A limited number of studies were performed to compare different stability measurement devices. The aim of the study was to evaluate the association between the implant stability and peri-implant vertical defect by using the new wireless RF analyser. Micro-textured rough-surfaced implants with diameters of 3.7 and 4.8 mm and with a length of 12 mm were used. The peak insertion torque was recorded with the help of the torque control system only during the implant placement. The peri-implant defects were created in millimetre increments ranging between 0 and 5 mm to the same extent on all implants. The RF analysis values were measured by using the RF analyser. Significant correlation was found between insertion torque (44.3 +/- 3 N cm) and implant stability quotient (ISQ) (all implants: r = 0.76, 3.7 mm diameter: r = 0.65, 4.8 mm diameter: r = 0.80). For 3.7 x 12-mm(2) implants, the mean ISQ values were 72.6 +/- 2.4, 69.8 +/- 2, 67.2 +/- 1.8, 64.3 +/- 1.9, 61.2 +/- 2 and 57.2 +/- 2.5 when peri-implant vertical defects were 0, 1, 2, 3, 4 and 5 mm; and the corresponding values were 76.5 +/- 2.2, 74.5 +/- 2.2, 72.3 +/- 2, 70 +/- 1.9, 67 +/- 1.9 and 63.4 +/- 2.3, respectively, for 4.8 x 12-mm(2) implants. All values were significantly different when compared with each other. The wireless RF analyser seems to be a suitable and reliable device to determine the implant stability. Peri-implant bone loss simulated by using acrylic models may result with a decrease in ISQ values for osseo-integrated implants measured by the RF analyser.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18422511     DOI: 10.1111/j.1365-2842.2007.01840.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  4 in total

1.  Determination of the dynamics of healing at the tissue-implant interface by means of microcomputed tomography and functional apparent moduli.

Authors:  Po-Chun Chang; Yang-Jo Seol; Steven A Goldstein; William V Giannobile
Journal:  Int J Oral Maxillofac Implants       Date:  2013 Jan-Feb       Impact factor: 2.804

2.  Reliability of the Resonance Frequency Analysis Values in New Prototype Transepithelial Abutments: A Prospective Clinical Study.

Authors:  María Guerrero-González; Francesca Monticelli; David Saura García-Martín; Mariano Herrero-Climent; Blanca Ríos-Carrasco; José-Vicente Ríos-Santos; Ana Fernández-Palacín
Journal:  Int J Environ Res Public Health       Date:  2020-09-16       Impact factor: 3.390

3.  Consequences of Peri-Implant Bone Loss in the Occlusal Load Transfer to the Supporting Bone in terms of Magnitude of Stress, Strain, and Stress Distribution: A Finite Element Analysis.

Authors:  Esteban Pérez-Pevida; David Chávarri-Prado; Markel Diéguez-Pereira; Alejandro Estrada-Martínez; Oier Montalbán-Vadillo; Antonio Jiménez-Garrudo
Journal:  Biomed Res Int       Date:  2021-09-01       Impact factor: 3.411

4.  The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets.

Authors:  Sang Ho Jun; Chang-Joo Park; Suk-Hyun Hwang; Youn Ki Lee; Cong Zhou; Hyon-Seok Jang; Jae-Jun Ryu
Journal:  Maxillofac Plast Reconstr Surg       Date:  2018-04-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.