Literature DB >> 18419562

Dual-energy X-ray absorptiometry (DXA) can accurately and nondestructively measure the body composition of small, free-living rodents.

Kalb T Stevenson1, Ian G van Tets.   

Abstract

Dual-energy x-ray absorptiometry (DXA) is a nondestructive technique that can potentially measure specific components of whole-body composition in free-living and lab-raised animals. Our aim was to test the ability of DXA to measure the composition of a common arvicoline rodent, the northern red-backed vole (Clethrionomys rutilus). We used a DXA apparatus to obtain measurements of fat mass (FM), lean mass (LM),bone mineral content, bone mineral density, and fat-free mass(FFM) in carcasses of free-living and lab-raised voles. We then used chemical carcass analysis to derive predictive algorithms for actual values of FM, total body water, total protein, total mineral, LM, and FFM. Unexplained error in the equations for all voles grouped collectively ranged from R(2) = 0.82 to R(2) = 0.98. The DXA FM measurement had the highest coefficient of variation, and it was higher for free-living voles than for lab-raised voles. However, FM can be determined by difference with excellent precision by using the FFM equation (R(2) = 0.98). We also derived corrective terms for passive integrated transponder-tagged animals. Thus, DXA is a nonlethal, nondestructive tool capable of precisely and accurately measuring many specific parameters of whole-body composition in small free-living and lab-raised rodents.

Entities:  

Mesh:

Year:  2008        PMID: 18419562     DOI: 10.1086/587096

Source DB:  PubMed          Journal:  Physiol Biochem Zool        ISSN: 1522-2152            Impact factor:   2.247


  6 in total

1.  Validation of Dual-energy X-Ray Absorptiometry to Predict Body Composition of Channel Catfish, Ictalurus punctatus.

Authors:  Maria S Johnson; Randall J Watts; Hugh S Hammer; Tim R Nagy; Stephen A Watts
Journal:  J World Aquac Soc       Date:  2016-07-04       Impact factor: 2.512

2.  Visceral fat mass determination in rodent: validation of dual-energy X-ray absorptiometry and anthropometric techniques in fat and lean rats.

Authors:  Maude Gerbaix; Lore Metz; Emeline Ringot; Daniel Courteix
Journal:  Lipids Health Dis       Date:  2010-12-09       Impact factor: 3.876

3.  The effect of implantation on scaffoldless three-dimensional engineered bone constructs.

Authors:  Michael J Smietana; Fatima N Syed-Picard; Jinjin Ma; Tatiana Kostrominova; Ellen M Arruda; Lisa M Larkin
Journal:  In Vitro Cell Dev Biol Anim       Date:  2009-06-16       Impact factor: 2.416

4.  Measuring body condition of lizards: a comparison between non-invasive dual-energy X-ray absorptiometry, chemical fat extraction and calculated indices.

Authors:  Guy Sion; Maggie J Watson; Amos Bouskila
Journal:  Front Zool       Date:  2021-01-05       Impact factor: 3.172

5.  The effects of hibernation and forced disuse (neurectomy) on bone properties in arctic ground squirrels.

Authors:  Lori K Bogren; Erin L Johnston; Zeinab Barati; Paula A Martin; Samantha J Wojda; Ian G Van Tets; Adrian D LeBlanc; Seth W Donahue; Kelly L Drew
Journal:  Physiol Rep       Date:  2016-05

6.  Changes in Body Composition of Old Rats at Different Time Points After Dexamethasone Administration.

Authors:  Maire Aru; Karin Alev; Ando Pehme; Priit Purge; Lauri Õnnik; Anu Ellam; Priit Kaasik; Teet Seene
Journal:  Curr Aging Sci       Date:  2019
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.