Literature DB >> 18418597

Correction of oral contrast artifacts in CT-based attenuation correction of PET images using an automated segmentation algorithm.

Alireza Ahmadian1, Mohammad R Ay, Javad H Bidgoli, Saeed Sarkar, Habib Zaidi.   

Abstract

PURPOSE: Oral contrast is usually administered in most X-ray computed tomography (CT) examinations of the abdomen and the pelvis as it allows more accurate identification of the bowel and facilitates the interpretation of abdominal and pelvic CT studies. However, the misclassification of contrast medium with high-density bone in CT-based attenuation correction (CTAC) is known to generate artifacts in the attenuation map (mumap), thus resulting in overcorrection for attenuation of positron emission tomography (PET) images. In this study, we developed an automated algorithm for segmentation and classification of regions containing oral contrast medium to correct for artifacts in CT-attenuation-corrected PET images using the segmented contrast correction (SCC) algorithm.
METHODS: The proposed algorithm consists of two steps: first, high CT number object segmentation using combined region- and boundary-based segmentation and second, object classification to bone and contrast agent using a knowledge-based nonlinear fuzzy classifier. Thereafter, the CT numbers of pixels belonging to the region classified as contrast medium are substituted with their equivalent effective bone CT numbers using the SCC algorithm. The generated CT images are then down-sampled followed by Gaussian smoothing to match the resolution of PET images. A piecewise calibration curve was then used to convert CT pixel values to linear attenuation coefficients at 511 keV.
RESULTS: The visual assessment of segmented regions performed by an experienced radiologist confirmed the accuracy of the segmentation and classification algorithms for delineation of contrast-enhanced regions in clinical CT images. The quantitative analysis of generated mumaps of 21 clinical CT colonoscopy datasets showed an overestimation ranging between 24.4% and 37.3% in the 3D-classified regions depending on their volume and the concentration of contrast medium. Two PET/CT studies known to be problematic demonstrated the applicability of the technique in clinical setting. More importantly, correction of oral contrast artifacts improved the readability and interpretation of the PET scan and showed substantial decrease of the SUV (104.3%) after correction.
CONCLUSIONS: An automated segmentation algorithm for classification of irregular shapes of regions containing contrast medium was developed for wider applicability of the SCC algorithm for correction of oral contrast artifacts during the CTAC procedure. The algorithm is being refined and further validated in clinical setting.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18418597     DOI: 10.1007/s00259-008-0756-7

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  25 in total

1.  Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults.

Authors:  Perry J Pickhardt; J Richard Choi; Inku Hwang; James A Butler; Michael L Puckett; Hans A Hildebrandt; Roy K Wong; Pamela A Nugent; Pauline A Mysliwiec; William R Schindler
Journal:  N Engl J Med       Date:  2003-12-01       Impact factor: 91.245

Review 2.  X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

Authors:  Paul E Kinahan; Bruce H Hasegawa; Thomas Beyer
Journal:  Semin Nucl Med       Date:  2003-07       Impact factor: 4.446

3.  Oral contrast medium in PET/CT: should you or shouldn't you?

Authors:  Ashley M Groves; Irfan Kayani; John C Dickson; Caroline Townsend; Ian Croasdale; Rizwan Syed; Nagesh Nagabushan; Sharon F Hain; Peter J Ell; Jamshed B Bomanji
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-06-04       Impact factor: 9.236

4.  Snakes, shapes, and gradient vector flow.

Authors:  C Xu; J L Prince
Journal:  IEEE Trans Image Process       Date:  1998       Impact factor: 10.856

5.  A computational approach to edge detection.

Authors:  J Canny
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1986-06       Impact factor: 6.226

Review 6.  Advances in Attenuation Correction Techniques in PET.

Authors:  Habib Zaidi; Marie-Louise Montandon; Abass Alavi
Journal:  PET Clin       Date:  2008-02-15

7.  PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients.

Authors:  A K Berthelsen; S Holm; A Loft; T L Klausen; F Andersen; L Højgaard
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-05-21       Impact factor: 9.236

8.  Effective methods to correct contrast agent-induced errors in PET quantification in cardiac PET/CT.

Authors:  Florian Büther; Lars Stegger; Mohammad Dawood; Felix Range; Michael Schäfers; Roman Fischbach; Thomas Wichter; Otmar Schober; Klaus P Schäfers
Journal:  J Nucl Med       Date:  2007-06-15       Impact factor: 10.057

9.  Cause and magnitude of the error induced by oral CT contrast agent in CT-based attenuation correction of PET emission studies.

Authors:  Elena Dizendorf; Thomas F Hany; Alfred Buck; Gustav K von Schulthess; Cyrill Burger
Journal:  J Nucl Med       Date:  2003-05       Impact factor: 10.057

10.  Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer.

Authors:  Ukihide Tateishi; Tetsuo Maeda; Tsuyoshi Morimoto; Mototaka Miyake; Yasuaki Arai; E Edmund Kim
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-05-26       Impact factor: 9.236

View more
  7 in total

1.  Comparative assessment of energy-mapping approaches in CT-based attenuation correction for PET.

Authors:  Mohammad R Ay; Maryam Shirmohammad; Saeed Sarkar; Arman Rahmim; Habib Zaidi
Journal:  Mol Imaging Biol       Date:  2011-02       Impact factor: 3.488

2.  A novel approach to assess the treatment response using Gaussian random field in PET.

Authors:  Mengdie Wang; Ning Guo; Guangshu Hu; Georges El Fakhri; Hui Zhang; Quanzheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

3.  The Netherlands protocol for standardisation and quantification of FDG whole body PET studies in multi-centre trials.

Authors:  Ronald Boellaard; Wim J G Oyen; Corneline J Hoekstra; Otto S Hoekstra; Eric P Visser; Antoon T Willemsen; Bertjan Arends; Fred J Verzijlbergen; Josee Zijlstra; Anne M Paans; Emile F I Comans; Jan Pruim
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-08-15       Impact factor: 9.236

4.  Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09-12       Impact factor: 9.236

5.  Diagnostic value of PET/CT for the staging and restaging of pediatric tumors.

Authors:  Margit Kleis; Heike Daldrup-Link; Katherine Matthay; Robert Goldsby; Ying Lu; Tibor Schuster; Carole Schreck; Philip W Chu; Randall A Hawkins; Benjamin L Franc
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-08-22       Impact factor: 9.236

Review 6.  Variants and Pitfalls in PET/CT Imaging of Gastrointestinal Cancers.

Authors:  Vetri Sudar Jayaprakasam; Viktoriya Paroder; Heiko Schöder
Journal:  Semin Nucl Med       Date:  2021-05-06       Impact factor: 4.802

Review 7.  Tumor quantification in clinical positron emission tomography.

Authors:  Bing Bai; James Bading; Peter S Conti
Journal:  Theranostics       Date:  2013-10-07       Impact factor: 11.556

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.