Literature DB >> 18418574

Transosseous arthroscopic repair of partial articular-surface supraspinatus tendon tears.

Mark Tauber1, Heiko Koller, Herbert Resch.   

Abstract

Partial articular-surface tendon avulsion (PASTA) lesions of the supraspinatus muscle represent a common cause for shoulder impairment and a preceding pathology for full-thickness tendon tears. Arthroscopic tendon repair is a possible surgical method of treatment. The purposes of cuff repair are anatomical tendon healing, prevention of tear size progression to completion and reduction of shoulder pain. In this report, we describe a transtendon arthroscopic technique of transosseous refixation of articular-side partial tears leaving the bursal layer of the supraspinatus tendon intact. A curved hollow needle is used to perform an all arthroscopic transosseous mattress suture. Thus, anatomical tendon-to-bone contact of the rotator cuff to the footprint is restored. Preliminary clinical results of 16 patients are convincing with significant pain relief and functional improvement.

Entities:  

Mesh:

Year:  2008        PMID: 18418574     DOI: 10.1007/s00167-008-0532-z

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  17 in total

1.  Histologic evidence of degeneration at the insertion of 3 rotator cuff tendons: a comparative study with human cadaveric shoulders.

Authors:  H Sano; H Ishii; G Trudel; H K Uhthoff
Journal:  J Shoulder Elbow Surg       Date:  1999 Nov-Dec       Impact factor: 3.019

2.  Transtendon arthroscopic repair of partial-thickness, articular surface tears of the rotator cuff.

Authors:  Ian K Y Lo; Stephen S Burkhart
Journal:  Arthroscopy       Date:  2004-02       Impact factor: 4.772

3.  Arthroscopic surgery for partial rotator cuff tears.

Authors:  Richard C Lehman; Clayton R Perry
Journal:  Arthroscopy       Date:  2003-09       Impact factor: 4.772

Review 4.  Débridement of partial-thickness tears of the rotator cuff without acromioplasty. Long-term follow-up and review of the literature.

Authors:  J E Budoff; R P Nirschl; E J Guidi
Journal:  J Bone Joint Surg Am       Date:  1998-05       Impact factor: 5.284

5.  Arthroscopic debridement and acromioplasty versus mini-open repair in the treatment of significant partial-thickness rotator cuff tears.

Authors:  S C Weber
Journal:  Arthroscopy       Date:  1999-03       Impact factor: 4.772

6.  Arthroscopic transtendon repair of partial-thickness articular-side tears of the rotator cuff: anatomical and clinical study.

Authors:  Junji Ide; Satoshi Maeda; Katsumasa Takagi
Journal:  Am J Sports Med       Date:  2005-08-10       Impact factor: 6.202

Review 7.  Arthroscopic treatment of rotator cuff disease.

Authors:  G M Gartsman
Journal:  J Shoulder Elbow Surg       Date:  1995 May-Jun       Impact factor: 3.019

8.  Partial-thickness articular surface supraspinatus tears: a new transtendon suture technique.

Authors:  Bernhard Waibl; Eduard Buess
Journal:  Arthroscopy       Date:  2005-03       Impact factor: 4.772

9.  Arthroscopic transosseous reinsertion of the rotator cuff.

Authors:  Nicholas Matis; Clemens Hübner; Erwin Aschauer; Herbert Resch
Journal:  Oper Orthop Traumatol       Date:  2006-03       Impact factor: 1.154

10.  Open acromioplasty does not prevent the progression of an impingement syndrome to a tear. Nine-year follow-up of 96 cases.

Authors:  P Hyvönen; S Lohi; P Jalovaara
Journal:  J Bone Joint Surg Br       Date:  1998-09
View more
  14 in total

1.  Arthroscopic transosseous (anchorless) rotator cuff repair.

Authors:  Raffaele Garofalo; Alessandro Castagna; Mario Borroni; Sumant G Krishnan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-20       Impact factor: 4.342

2.  Arthroscopic transtendon repair of partial articular-sided supraspinatus tendon avulsion.

Authors:  Giovanni Battista Vinanti; Alberto Rossato; Daniele Scrimieri; Massimo Petrera
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-22       Impact factor: 4.342

3.  Trans-tendon arthroscopic repair for partial-thickness articular side tears of the rotator cuff.

Authors:  Young-Jin Seo; Yon-Sik Yoo; Do-Young Kim; Kyu-Cheol Noh; Nagraj S Shetty; Jae-Hyung Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-01-13       Impact factor: 4.342

4.  Transtendon, double-row, transosseous-equivalent arthroscopic repair of partial-thickness, articular-surface rotator cuff tears.

Authors:  Matthew F Dilisio; Lindsay R Miller; Laurence D Higgins
Journal:  Arthrosc Tech       Date:  2014-09-08

5.  Arthroscopic transosseous rotator cuff repair: the eight-shape technique.

Authors:  Claudio Chillemi; Matteo Mantovani; Marcello Osimani; Alessandro Castagna
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-01-25

6.  Arthroscopic Debridement of the Thrower's Shoulder: Less Is More.

Authors:  Paul E Caldwell; Dustin C Dyer; Sara E Pearson
Journal:  Arthrosc Tech       Date:  2016-12-05

7.  I.S.Mu.L.T - Rotator Cuff Tears Guidelines.

Authors:  Francesco Oliva; Eleonora Piccirilli; Michela Bossa; Alessio Giai Via; Alessandra Colombo; Claudio Chillemi; Giuseppe Gasparre; Leonardo Pellicciari; Edoardo Franceschetti; Clelia Rugiero; Alessandro Scialdoni; Filippo Vittadini; Paola Brancaccio; Domenico Creta; Angelo Del Buono; Raffaele Garofalo; Francesco Franceschi; Antonio Frizziero; Asmaa Mahmoud; Giovanni Merolla; Simone Nicoletti; Marco Spoliti; Leonardo Osti; Johnny Padulo; Nicola Portinaro; Gianfranco Tajana; Alex Castagna; Calogero Foti; Stefano Masiero; Giuseppe Porcellini; Umberto Tarantino; Nicola Maffulli
Journal:  Muscles Ligaments Tendons J       Date:  2016-02-13

8.  Partial-thickness articular surface rotator cuff tears: an all-inside repair technique.

Authors:  Edwin E Spencer
Journal:  Clin Orthop Relat Res       Date:  2010-06       Impact factor: 4.176

Review 9.  Systematic review: what surgical technique provides the best outcome for symptomatic partial articular-sided rotator cuff tears?

Authors:  Matthew Bollier; Kevin Shea
Journal:  Iowa Orthop J       Date:  2012

10.  Partial articular supraspinatus tendon avulsion: Should we repair? A systematic review of the evidence.

Authors:  Duncan Tennent; Gemma Green
Journal:  Shoulder Elbow       Date:  2019-08-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.