Literature DB >> 18417507

Reference values for peak flow and FEV1 variation in healthy schoolchildren using home spirometry.

A F J Brouwer1, R J Roorda, E J Duiverman, P L P Brand.   

Abstract

Current reference values for diurnal peak flow variation in healthy children (median 8.2%; 95th percentile 31%) are so high that considerable overlap exists with those of asthmatic children. These values have been obtained using written peak flow diaries, which are unreliable. The aim of the present study was to obtain reliable reference values for the variation in peak flow and forced expiratory volume in one second (FEV(1)) in healthy schoolchildren using home spirometry with electronic data storage. Healthy schoolchildren (n = 204; 100 males) aged 6-16 yrs measured their peak flow and FEV(1) twice daily for 2 weeks using an electronic home spirometer. The variation in peak flow and FEV(1) were calculated as a diurnal amplitude as a percentage of the day's mean. The mean peak flow variation was 6.2% (95th percentile 12.3%) and the mean FEV(1) variation was 5.7% (95th percentile 11.8%). Using home spirometry with electronic data storage, healthy schoolchildren show considerably less peak flow and forced expiratory volume in one second variation than previously reported on the basis of written peak flow diaries. Being the 95th percentiles of the distributions in healthy children, a peak flow variation of 12.3% and an forced expiratory volume in one second variation of 11.8% are suggested as cut-off values for disease when using home spirometry.

Entities:  

Mesh:

Year:  2008        PMID: 18417507     DOI: 10.1183/09031936.00148107

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  6 in total

Review 1.  Asthma outcomes: pulmonary physiology.

Authors:  Robert S Tepper; Robert S Wise; Ronina Covar; Charles G Irvin; Carolyn M Kercsmar; Monica Kraft; Mark C Liu; George T O'Connor; Stephen P Peters; Ronald Sorkness; Alkis Togias
Journal:  J Allergy Clin Immunol       Date:  2012-03       Impact factor: 10.793

2.  A joint ERS/ATS policy statement: what constitutes an adverse health effect of air pollution? An analytical framework.

Authors:  George D Thurston; Howard Kipen; Isabella Annesi-Maesano; John Balmes; Robert D Brook; Kevin Cromar; Sara De Matteis; Francesco Forastiere; Bertil Forsberg; Mark W Frampton; Jonathan Grigg; Dick Heederik; Frank J Kelly; Nino Kuenzli; Robert Laumbach; Annette Peters; Sanjay T Rajagopalan; David Rich; Beate Ritz; Jonathan M Samet; Thomas Sandstrom; Torben Sigsgaard; Jordi Sunyer; Bert Brunekreef
Journal:  Eur Respir J       Date:  2017-01-11       Impact factor: 16.671

3.  Asthma-related lung function, sleep quality, and sleep duration in urban children.

Authors:  Daphne Koinis-Mitchell; Sheryl J Kopel; Ronald Seifer; Monique LeBourgeois; Elizabeth L McQuaid; Cynthia A Esteban; Julie Boergers; Jack Nassau; Michael Farrow; Gregory K Fritz; Robert B Klein
Journal:  Sleep Health       Date:  2017-04-11

4.  Utility of a portable hand-held forced expiratory volume in 1 second meter for monitoring asthma in an inner-city school setting.

Authors:  Jonathan M Gaffin; Joseph S Zhou; Qiling Cai; Carter R Petty; Chunxia Fu; William J Sheehan; Sachin Baxi; Ann Bailey; Diane R Gold; Wanda Phipatanakul
Journal:  Ann Allergy Asthma Immunol       Date:  2016-07-14       Impact factor: 6.347

5.  Peak expiratory flow among healthy children aged 5-14 years in China.

Authors:  Yanhong Lu; Jinping Zheng; Chuanhe Liu; Tao Ai; Ning Wang; Ning Meng; Shuo Li; Ronghua Luo; Xiaomei Ren; Wujun Jiang; Yi Gao; Chuangli Hao
Journal:  J Thorac Dis       Date:  2018-03       Impact factor: 2.895

6.  Vortex Whistle and Smart Phone Application for Peak Flow Recordings in Asthmatic Children: A Feasibility Study.

Authors:  Ingvild Bruun Mikalsen; Damoun Nassehi; Knut Øymar
Journal:  Telemed J E Health       Date:  2018-12-20       Impact factor: 3.536