OBJECTIVE: To compare rebonding of orthodontic brackets based on the hypothesis that no difference would be found between the adhesive systems with respect to shear bond strength, mode of failure, and clinical failure rates.
MATERIALS AND METHODS: The three adhesive systems included two self-etch primers (Transbond and M-Bond) and a conventional phosphoric acid etch (Rely-a-Bond). The sample size was 20 premolars for each adhesive system. The shear bond strength was tested 24 hours after bracket bonding with the bonding/debonding procedures repeated two times after the first debonding. Bond strength, adhesive remnant index (ARI), and failure sites were evaluated for each debonding. Statistical analysis consisted of a two-way analysis of variance (ANOVA) followed by Scheffè analysis. The clinical portion evaluated 15 patients over a 12-month period.
RESULTS: The mean shear bond strengths after the first, second, and third debondings for Rely-a-Bond were 8.4 +/- 1.8, 10.3 +/- 2.4, and 14.1 +/- 3.3 MPa, respectively; for Transbond 11.1 +/- 4.6, 13.6 +/- 4.5, and 12.9 +/- 4.4 MPa, respectively; and for M-Bond 8.7 +/- 2.7, 10.4 +/- 2.4, and 12.4 +/- 3.4 MPa, respectively. After the three debondings the mean shear bond strength increased significantly from the first to the third debonding for Rely-a-Bond and M-bond (P </= .001), but did not change for Transbond (P = .199).
CONCLUSIONS: The original hypothesis is not rejected. The two self-etching primers showing higher or comparable bond strength to the conventional phosphoric etch with less adhesive remnant on the enamel surface after the first debonding. With repeated bonding/debonding, the differences in the bond strength, ARI, and failure site were not significantly different. There was no difference in the clinical performance of the three adhesive systems (P = .667).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18416614     DOI: 10.2319/022307-90.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  11 in total

1.  Optimal enamel conditioning strategy for rebonding orthodontic brackets: a laboratory study.

Authors:  Qi-Feng Zhang; Hua Yao; Zhi-Yong Li; Li Jin; Hui-Ming Wang
Journal:  Int J Clin Exp Med       Date:  2014-09-15

2.  Use of the Er,Cr:YSGG laser for removing remnant adhesive from the enamel surface in rebonding of orthodontic brackets.

Authors:  Katsunori Koide; Satoshi Tanaka; Toshiya Endo
Journal:  Odontology       Date:  2019-08-26       Impact factor: 2.634

3.  Er,Cr:YSGG Laser as a Novel Method for Rebonding Failed Ceramic Brackets.

Authors:  Aydin Sohrabi; Sanaz Jafari; Soodabeh Kimyai; Sahand Rikhtehgaran
Journal:  Photomed Laser Surg       Date:  2016-08-29       Impact factor: 2.796

4.  The effects of application time of a self-etching primer and debonding methods on bracket bond strength.

Authors:  Brandon C Parrish; Thomas R Katona; Serkis C Isikbay; Kelton T Stewart; Katherine S Kula
Journal:  Angle Orthod       Date:  2011-07-28       Impact factor: 2.079

5.  Effect of multiple debonding sequences on shear bond strength of new stainless steel brackets.

Authors:  Ladan Eslamian; Ali Borzabadi-Farahani; Pegah Tavakol; Ali Tavakol; Nazila Amini; Edward Lynch
Journal:  J Orthod Sci       Date:  2015 Apr-Jun

6.  Effect of Removal of Enamel on Rebonding Strength of Resin Composite to Enamel.

Authors:  L Kilponen; L Lassila; M Tolvanen; J Varrela; P K Vallittu
Journal:  Biomed Res Int       Date:  2016-09-20       Impact factor: 3.411

7.  Shear Bond Strength of Rebonded Ceramic Brackets Using Four Different Methods of Adhesive Removal.

Authors:  Amir Hossein Mirhashemi; Mohammad Hashem Hosseini; Nasim Chiniforoush; Armin Soudi; Meisam Moradi
Journal:  J Dent (Tehran)       Date:  2018-01

8.  Comparison of multiple rebond shear strengths of debonded brackets after preparation with sandblasting and CO2 laser.

Authors:  Mojgan Kachoei; Amir Mohammadi; Maziar Esmaili Moghaddam; Sahand Rikhtegaran; Mahmoud Pourghaznein; Sajjad Shirazi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2016-08-17

9.  The effect of resin cement type and cleaning method on the shear bond strength of resin cements for recementing restorations.

Authors:  Roodabeh Koodaryan; Ali Hafezeqoran; Amin Khakpour Maleki
Journal:  J Adv Prosthodont       Date:  2017-04-06       Impact factor: 1.904

10.  Effect of the caries-protective self-assembling peptide P11-4 on shear bond strength of metal brackets.

Authors:  Thomas Knaup; Heike Korbmacher-Steiner; Anahita Jablonski-Momeni
Journal:  J Orofac Orthop       Date:  2020-09-02       Impact factor: 1.938

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.