Literature DB >> 18412505

Numerical study of the uniformity of balloon-expandable stent deployment.

P Mortier1, M De Beule, S G Carlier, R Van Impe, B Verhegghe, P Verdonck.   

Abstract

Stents are small tubelike structures, implanted in coronary and peripheral arteries to reopen narrowed vessel sections. This endovascular intervention remains suboptimal, as the success rate is limited by restenosis. This renarrowing of a stented vessel is related to the arterial injury caused by stent-artery and balloon-artery interactions, and a local subsequent inflammatory process. Therefore, efforts to optimize the stent deployment remain very meaningful. Several authors have studied with finite element modeling the mechanical behavior of balloon-expandable stents, but none of the proposed models incorporates the folding pattern of the balloon. We developed a numerical model in which the CYPHER stent is combined with a realistic trifolded balloon. In this paper, the impact of several parameters such as balloon length, folding pattern, and relative position of the stent with respect to the balloon catheter on the free stent expansion has been investigated. Quantitative validation of the modeling strategy shows excellent agreement with data provided by the manufacturer and, therefore, the model serves as a solid basis for further investigations. The parametric analyses showed that both the balloon length and the folding pattern have a considerable influence on the uniformity and symmetry of the transient stent expansion. Consequently, this approach can be used to select the most appropriate balloon length and folding pattern for a particular stent design in order to optimize the stent deployment. Furthermore, it was demonstrated that small positioning inaccuracies may change the expansion behavior of a stent. Therefore, the placement of the stent on the balloon catheter should be accurately carried out, again in order to decrease the endothelial damage.

Entities:  

Mesh:

Year:  2008        PMID: 18412505     DOI: 10.1115/1.2904467

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  5 in total

Review 1.  Validation of computational models in biomechanics.

Authors:  H B Henninger; S P Reese; A E Anderson; J A Weiss
Journal:  Proc Inst Mech Eng H       Date:  2010       Impact factor: 1.617

2.  Numerical Analysis for Non-Uniformity of Balloon-Expandable Stent Deployment Driven by Dogboning and Foreshortening.

Authors:  Ganesh B Rahinj; Harshit S Chauhan; Martin L Sirivella; Menta V Satyanarayana; Laxminarayanan Ramanan
Journal:  Cardiovasc Eng Technol       Date:  2021-08-24       Impact factor: 2.305

3.  Automated generation of a finite element stent model.

Authors:  Peter Mortier; Matthieu De Beule; Denis Van Loo; Bert Masschaele; Pascal Verdonck; Benedict Verhegghe
Journal:  Med Biol Eng Comput       Date:  2008-10-18       Impact factor: 3.079

4.  Design optimization of stent and its dilatation balloon using kriging surrogate model.

Authors:  Hongxia Li; Tao Liu; Minjie Wang; Danyang Zhao; Aike Qiao; Xue Wang; Junfeng Gu; Zheng Li; Bao Zhu
Journal:  Biomed Eng Online       Date:  2017-01-11       Impact factor: 2.819

5.  Multi-objective optimization of coronary stent using Kriging surrogate model.

Authors:  Hongxia Li; Junfeng Gu; Minjie Wang; Danyang Zhao; Zheng Li; Aike Qiao; Bao Zhu
Journal:  Biomed Eng Online       Date:  2016-12-28       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.