Literature DB >> 18412082

Percutaneous management of cyanosis in Fontan patients using Amplatzer occluders.

Jozef Masura1, Lucia Bordacova, Lucia Borodacova, Peter Tittel, Pavel Berden, Tomaz Podnar.   

Abstract

OBJECTIVES: To determine causes of cyanosis and to evaluate percutaneous management of cyanosis in a group of consecutive Fontan patients.
BACKGROUND: A variety of communications allow a right-to-left shunt in Fontan circulation causing cyanosis and these communications are amenable to percutaneous closure.
METHODS: Between November 1997 and November 2007, 45 consecutive patients ranging in age from 2.5 to 26 years (median 8 years) with Fontan circulation and cyanosis underwent cardiac catheterization and percutaneous closure of superfluous communications using different types of Amplatzer occluders.
RESULTS: Altogether, 51 communications were detected and 50 of them were closed. In 5 patients (11.1%), multiple communications were present and were closed. Fenestration was detected in 37 of 41 patients (90.2%) after total cavopulmonary connection and all were closed by Amplatzer septal occluders. Five venous collaterals were revealed in 3 of 41 patients (7.3%) with total cavopulmonary anastomosis and were closed by Amplatzer vascular plugs. In 3 patients, lateral tunnel leaks were detected and were closed by Amplatzer PFO occluders. In 4 patients after Kawashima operation, 3 major pulmonary arterio-venous malformations and single venous collateral contributed to the cyanosis and all were closed using Amplatzer vascular plugs.
CONCLUSIONS: Different communications cause cyanosis in Fontan patients. Progressive decline of percutaneous oxygen saturation is suggestive of development of venous collaterals or pulmonary arteriovenous malformations. Superfluous communications are amenable to percutaneous closure using various types of Amplatzer occluders. A novel use of an Amplatzer PFO occluder for the percutaneous closure of a lateral tunnel leak is described. 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18412082     DOI: 10.1002/ccd.21540

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  4 in total

1.  Closure of conduit fenestration after extracardiac Fontan procedure using Amplatzer vascular plug: comparison with detachable coil.

Authors:  Soo In Jeong; June Huh; Heung Jae Lee; Ji Hyuk Yang; Tae Gook Jun; I Seok Kang
Journal:  Pediatr Cardiol       Date:  2009-10-15       Impact factor: 1.655

2.  Unusual systemic venous Collateral channels to left atrium causing desaturation after Fontan operation closed percutaneously.

Authors:  Ashutosh Marwah; Sanjay Khatri; Savitri Shrivastava; Krishna S Iyer
Journal:  Ann Pediatr Cardiol       Date:  2013-07

3.  Impact on clinical outcomes from transcatheter closure of the Fontan fenestration: A systematic review and meta-analysis.

Authors:  Christopher E Greenleaf; Zhia Ning Lim; Wen Li; Damien J LaPar; Jorge D Salazar; Antonio F Corno
Journal:  Front Pediatr       Date:  2022-10-04       Impact factor: 3.569

4.  Trans catheter device closure of a large azygos vein in adult patient with systemic venous collateral development after the bidirectional Glenn shunt.

Authors:  Zahra Khajali; Ata Firouzi; Pooneh Pashapour; Homa Ghaderian
Journal:  J Cardiovasc Thorac Res       Date:  2021-01-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.