Literature DB >> 18406914

Clinical practice and quality assurance challenges in modern brachytherapy sources and dosimetry.

Wayne M Butler1, Gregory S Merrick.   

Abstract

Modern brachytherapy has led to effective treatments through the establishment of broadly applicable dosimetric thresholds for maximizing survival with minimal morbidity. Proper implementation of recent dosimetric consensus statements and quality assurance procedures is necessary to maintain the established level of safety and efficacy. This review classifies issues as either "systematic" or "stochastic" in terms of their impact on large groups or individual patients, respectively. Systematic changes affecting large numbers of patients occur infrequently and include changes in source dosimetric parameters, prescribing practice, dose calculation formalism, and improvements in calculation algorithms. The physicist must be aware of how incipient changes accord with previous experience. Stochastic issues involve procedures that are applied to each patient individually. Although ample guidance for quality assurance of brachytherapy sources exists, some ambiguities remain. The latest American Association of Physicists in Medicine guidance clarifies what is meant by independent assay, changes source sampling recommendations, particularly for sources in sterile strands and sterile preassembled needles, and modifies action level thresholds. The changing environment of brachytherapy has not changed the fact that the prime responsibility for quality assurance in brachytherapy lies with the institutional medical physicist.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18406914     DOI: 10.1016/j.ijrobp.2007.08.084

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  HDR and PDR 192Ir source activity control procedures, as the part of the quality assurance system at Brachytherapy Department of Greater Poland Cancer Centre.

Authors:  Grzegorz Zwierzchowski; Barbara Błasiak; Patrycja Stefaniak; Grzegorz Bielęda
Journal:  J Contemp Brachytherapy       Date:  2009-10-08

2.  Efficacy and safety of 3D printing coplanar template-assisted iodine-125 seed implantation as palliative treatment for inoperable pancreatic cancer.

Authors:  Baohu Wang; Bin Qiu; Linlin Wu; Yu'e Liu; Jingxian Zhang; Ruoyu Wang; Kaixian Zhang; Junjie Wang
Journal:  J Contemp Brachytherapy       Date:  2022-03-28
  2 in total