Literature DB >> 18406909

Quality assurance procedures for stereotactic body radiation therapy.

James M Galvin1, Greg Bednarz.   

Abstract

Cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) are established treatment modalities. Initial implementations of these techniques rigidly attached frames to the patient's head for single-fraction treatments. The head frame accommodates an external fiducial marker system that is a reliable reference for targets within the cranium and accurately links the imaging equipment used for treatment planning to the treatment device. Fractionated SRT treatments use noninvasive "relocatable"-type head immobilization that fixes to the patient's head and face features. Clearly defined quality assurance (QA) procedures exist for both cranial SRS and SRT but are not as well developed for extracranial SRT. Procedures for demonstrating the geometric relationship between the planning imaging and treatment have to some degree copied the techniques used for intracranial stereotactic irradiation. However, there are some unique QA issues that are specific to extracranial irradiation. One major consideration is the large number of methodologies available for stereotactic body radiation therapy. In addition to the variety of integrated image-guided frameless systems, there are immobilization devices (called body frame systems) that use a fiducial reference system similar to the cranial devices. This article describes generic QA approaches that can be adapted to the various stereotactic body radiation therapy methodologies.

Entities:  

Mesh:

Year:  2008        PMID: 18406909     DOI: 10.1016/j.ijrobp.2007.10.002

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  4 in total

1.  Implementation of an in-house visual feedback system for motion management during radiation therapy.

Authors:  Vi Nhan V Nguyen; David C Ellerbusch; Ashley J Cetnar; Joshua A James; Brian Wang
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

Review 2.  Isocenter verification for linac-based stereotactic radiation therapy: review of principles and techniques.

Authors:  Pejman Rowshanfarzad; Mahsheed Sabet; Daryl J O'Connor; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

3.  A randomised comparison of three different immobilisation devices for thoracic and abdominal cancers.

Authors:  Catherine Hubie; Maddison Shaw; Sean Bydder; Jonny Lane; Gemma Waters; Megan McNabb; Rachel Kearvell; Alicia Concannon; Chrianna Bharat; Rob Appleyard
Journal:  J Med Radiat Sci       Date:  2016-12-20

4.  Clinical Evaluation of a Two-dimensional Liquid-Filled Ion chamber Detector Array for Verification of High Modulation Small Fields in Radiotherapy.

Authors:  Miljenko Markovic; Ganesh Narayanasamy; Sotirios Stathakis; Panayiotis Mavroidis; Ines-Ana Jurkovic; Daniel Saenz; Niko Papanikolaou
Journal:  J Med Phys       Date:  2019 Apr-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.