Pressure profile in the caudal extradural space of standing horses before and after extradural drug administration.

Isabelle Iff1, Martina Mosing, Yves Moens.   

Abstract

The objectives of this study were to measure the pressure in the caudal extradural space of standing horses and to evaluate the usefulness of pressure waves to identify correct needle placement. Caudal extradural pressure was measured in 12 healthy horses. The pressure and any extradural pressure waves were recorded for 3min after puncture, for 1min after testing for lack of resistance (LOR), and for 10min after lidocaine injection. Successful extradural drug administration was confirmed in all horses. The median extradural pressure findings after puncture, after LOR, immediately after injection and 10min after needle placement were -1.60kPa (range -2.27 to 1.33kPa), -0.67kPa (-2.27 to 5.73kPa), 5.00kPa (0.93 to 9.87kPa) and 0.13kPa (-0.67 to 4.53kPa), respectively. Extradural pressure waves were not always present. Extradural space pressure was sub-atmospheric in most horses and extradural injection significantly increased this pressure for up to 10min. Extradural pressure waves had limited usefulness in the confirmation of the correct placement of the needle.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18406643     DOI: 10.1016/j.tvjl.2007.10.024

Source DB:  PubMed          Journal:  Vet J        ISSN: 1090-0233            Impact factor:   2.688


  2 in total

1.  Limitations of the use of pressure waves to verify correct epidural needle position in dogs.

Authors:  Chiara Adami; Alessandra Bergadano; Claudia Spadavecchia
Journal:  Vet Med Int       Date:  2013-06-18

Review 2.  Etiology and use of the "hanging drop" technique: a review.

Authors:  Ludmil Todorov; Timothy VadeBoncouer
Journal:  Pain Res Treat       Date:  2014-04-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.