Literature DB >> 18405811

Effects of Class II activator and Class II activator high-pull headgear combination on the mandible: a 3-dimensional finite element stress analysis study.

Cağri Ulusoy1, Nilüfer Darendeliler.   

Abstract

INTRODUCTION: The aim of this study was to evaluate the effects of the Class II activator and the Class II activator high-pull headgear (HG) combination on the mandible with 3-dimensional (3D) finite element stress analysis.
METHODS: A 3D finite element model of the mandible was constructed from a dry human mandible. To investigate the effects of the Class II activator, a 3D model of the lower part of this appliance was constructed and fixed on the mandibular model. The Class II activator high-pull headgear model was established as described, and an extraoral traction force of 350 g was directed from the middle of the Class II activator to the top of the mandibular condyle. The stress regions were studied with the finite element method.
RESULTS: The regions near the muscle attachment areas were affected the most. The inner part of the coronoid process and the gonial area had the maximum stress values.
CONCLUSIONS: Both functional appliances can cause morphologic changes on the mandible by activating the masticatory muscles to change the growth direction.

Entities:  

Mesh:

Year:  2008        PMID: 18405811     DOI: 10.1016/j.ajodo.2007.10.032

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  7 in total

1.  Effects of the advanced mandibular spring on mandibular retrognathia treatment: a three-dimensional finite element study.

Authors:  Cheng Zhu; Ruomei Li; Lingjun Yuan; Yikan Zheng; Yu Jin; Hairui Li; Chao Liu; Lunguo Xia; Bing Fang
Journal:  BMC Oral Health       Date:  2022-07-05       Impact factor: 3.747

2.  Finite element analysis comparison of plate designs in managing fractures involving the mental foramen.

Authors:  Neralla Mahathi; Emmanuel Azariah; C Ravindran
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2013-04-30

3.  Evaluation of stress changes in the maxilla with fixed functional appliances-A 3D FEM study.

Authors:  Balaji Kendre; Anil Kumar; K Nillian Shetty; Gautham Hedge; Vinay Umale; Rohit Kulshrestha
Journal:  J Orthod Sci       Date:  2021-07-09

4.  Evaluation of displacements and stress changes in the maxillo-mandibular complex with fixed functional appliance skeletally anchored on mandible using miniplates: A finite element study.

Authors:  Davender Kumar; Rekha Sharma; Vinni Arora; Nameksh Raj Bhupali; Neha Tuteja
Journal:  J Orthod Sci       Date:  2022-08-24

5.  Stress Analysis of a Class II MO-Restored Tooth Using a 3D CT-Based Finite Element Model.

Authors:  Yiu Pong Chan; Chak Yin Tang; Bo Gao
Journal:  Int J Biomater       Date:  2012-07-14

Review 6.  Tissue Specific Promoters in Colorectal Cancer.

Authors:  A R Rama; A Aguilera; C Melguizo; O Caba; J Prados
Journal:  Dis Markers       Date:  2015-11-15       Impact factor: 3.434

7.  A new method for the treatment of unilateral posterior cross-bite: a three-dimensional finite element stress analysis study.

Authors:  Çağrı Ulusoy; Merve Dogan
Journal:  Prog Orthod       Date:  2018-08-27       Impact factor: 2.750

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.