Abstract

Megavoltage cone-beam computed tomography (MVCBCT) imaging systems are now available for image-guided radiation therapy delivery and verification. In order to use the three-dimensional anatomical information for dose calculation, the MVCBCT image must provide accurate electron density. This work proposes a new method that has been developed to correct for the cupping and missing data artifacts seen on MVCBCT images of the head and neck region. It uses a conventional kilovoltage CT (kVCT) image as a reference for electron density and rigid registration with a MVCBCT image to obtain correction factors. Dose calculations performed on MVCBCT images corrected with the proposed method agree with calculations done on kVCT images within +/- 1% on phantoms. With patients images the agreement is within +/- 13% above the shoulders and +/- 5% below the shoulder line. This level of dose calculation accuracy allows the use of MVCBCT images for dose verification purposes.

Entities:  

Mesh:

Year:  2008        PMID: 18404926     DOI: 10.1118/1.2839146

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Imaging study of pseudo-CT images of superposed ultrasound deformation fields acquired in radiotherapy based on step-by-step local registration.

Authors:  Hongfei Sun; Tao Lin; Kai Xie; Liugang Gao; Jianfeng Sui; Xinye Ni
Journal:  Med Biol Eng Comput       Date:  2018-10-15       Impact factor: 2.602

2.  Feasibility of improving cone-beam CT number consistency using a scatter correction algorithm.

Authors:  Jun Li; Weiguang Yao; Ying Xiao; Yan Yu
Journal:  J Appl Clin Med Phys       Date:  2013-11-04       Impact factor: 2.102

3.  Feasibility of MV CBCT-based treatment planning for urgent radiation therapy: dosimetric accuracy of MV CBCT-based dose calculations.

Authors:  Mareike Held; Penny K Sneed; Shannon E Fogh; Jean Pouliot; Olivier Morin
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

4.  Correction of megavoltage cone-beam CT images of the pelvic region based on phantom measurements for dose calculation purposes.

Authors:  Jean-François Aubry; Joey Cheung; Olivier Morin; Alexander Gottschalk; Luc Beaulieu; Jean Pouliot
Journal:  J Appl Clin Med Phys       Date:  2009-01-27       Impact factor: 2.102