Literature DB >> 18404225

On the electrodeposition of titanium in ionic liquids.

F Endres1, S Zein El Abedin, A Y Saad, E M Moustafa, N Borissenko, W E Price, G G Wallace, D R MacFarlane, P J Newman, A Bund.   

Abstract

The ability to electrodeposit titanium at low temperatures would be an important breakthrough for making corrosion resistant layers on a variety of technically important materials. Ionic liquids have often been considered as suitable solvents for the electrodeposition of titanium. In the present paper we have extensively investigated whether titanium can be electrodeposited from its halides (TiCl(4), TiF(4), TiI(4)) in different ionic liquids, namely1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)amide ([EMIm]Tf(2)N), 1-butyl-1-methylpyrrolidinium bis(trifluoromethyl-sulfonyl)amide ([BMP]Tf(2)N), and trihexyltetradecyl-phosphonium bis(trifluoromethylsulfonyl)amide ([P(14,6,6,6)]Tf(2)N). Cyclic voltammetry and EQCM measurements show that, instead of elemental Ti, only non-stoichiometric halides are formed, for example with average stoichiometries of TiCl(0.2), TiCl(0.5) and TiCl(1.1). In situ STM measurements show that-in the best case-an ultrathin layer of Ti or TiCl(x) with thickness below 1 nm can be obtained. In addition, results from both electrochemical and chemical reduction experiments of TiCl(4) in a number of these ionic liquids support the formation of insoluble titanium cation-chloride complex species often involving the solvent. Solubility studies suggest that TiCl(3) and, particularly, TiCl(2) have very limited solubility in these Tf(2)N based ionic liquids. Therefore it does not appear possible to reduce Ti(4+) completely to the metal in the presence of chloride. Successful deposition processing for titanium in ionic liquids will require different maybe tailor-made titanium precursors that avoid these problems.

Entities:  

Year:  2008        PMID: 18404225     DOI: 10.1039/b800353j

Source DB:  PubMed          Journal:  Phys Chem Chem Phys        ISSN: 1463-9076            Impact factor:   3.676


  2 in total

Review 1.  Ionic-liquid materials for the electrochemical challenges of the future.

Authors:  Michel Armand; Frank Endres; Douglas R MacFarlane; Hiroyuki Ohno; Bruno Scrosati
Journal:  Nat Mater       Date:  2009-07-24       Impact factor: 43.841

2.  Biocompatibility of Four Common Orthopedic Biomaterials Following a High-Salt Diet: An In Vivo Study.

Authors:  Mathieu Lecocq; Cécile Bernard; Marie Solenne Felix; Jean-Marc Linares; Julien Chaves-Jacob; Patrick Decherchi; Erick Dousset
Journal:  Int J Mol Sci       Date:  2017-07-11       Impact factor: 5.923

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.