Study of the motion artefacts of skin-mounted inertial sensors under different attachment conditions.

A Forner-Cordero1, M Mateu-Arce, I Forner-Cordero, E Alcántara, J C Moreno, J L Pons.   

Abstract

A common problem shared by accelerometers, inertial sensors and any motion measurement method based on skin-mounted sensors is the movement of the soft tissues covering the bones. The aim of this work is to propose a method for the validation of the attachment of skin-mounted sensors. A second-order (mass-spring-damper) model was proposed to characterize the behaviour of the soft tissue between the bone and the sensor. Three sets of experiments were performed. In the first one, different procedures to excite the system were evaluated to select an adequate excitation stimulus. In the second one, the selected stimulus was applied under varying attachment conditions while the third experiment was used to test the model. The heel drop was chosen as the excitation method because it showed lower variability and could discriminate between different attachment conditions. There was, in agreement with the model, a trend to increase the natural frequency of the system with decreasing accelerometer mass. An important result is the development of a standard procedure to test the bandwidth of skin-mounted inertial sensors, such as accelerometers mounted on the skin or markers heavier than a few grams.

Mesh:

Year:  2008        PMID: 18401071     DOI: 10.1088/0967-3334/29/4/N01

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  22 in total

1.  Reliability of the step phase detection using inertial measurement units: pilot study.

Authors:  Salvatore Sessa; Massimiliano Zecca; Luca Bartolomeo; Takamichi Takashima; Hiroshi Fujimoto; Atsuo Takanishi
Journal:  Healthc Technol Lett       Date:  2015-03-31

2.  Measuring movement symmetry using tibial-mounted accelerometers for people recovering from total knee arthroplasty.

Authors:  Cory L Christiansen; Michael J Bade; Roger J Paxton; Jennifer E Stevens-Lapsley
Journal:  Clin Biomech (Bristol, Avon)       Date:  2015-05-09       Impact factor: 2.063

3.  Criterion and construct validity of prosthesis-integrated measurement of joint moment data in persons with transtibial amputation.

Authors:  Goeran Fiedler; Brooke Slavens; Roger O Smith; Douglas Briggs; Brian J Hafner
Journal:  J Appl Biomech       Date:  2014-03-04       Impact factor: 1.833

Review 4.  Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review.

Authors:  Valentina Camomilla; Elena Bergamini; Silvia Fantozzi; Giuseppe Vannozzi
Journal:  Sensors (Basel)       Date:  2018-03-15       Impact factor: 3.576

Review 5.  The Use of Wearable Sensors for Preventing, Assessing, and Informing Recovery from Sport-Related Musculoskeletal Injuries: A Systematic Scoping Review.

Authors:  Ezio Preatoni; Elena Bergamini; Silvia Fantozzi; Lucie I Giraud; Amaranta S Orejel Bustos; Giuseppe Vannozzi; Valentina Camomilla
Journal:  Sensors (Basel)       Date:  2022-04-22       Impact factor: 3.847

6.  A portable system for collecting anatomical joint angles during stair ascent: a comparison with an optical tracking device.

Authors:  Jeroen H M Bergmann; Ruth E Mayagoitia; Ian C H Smith
Journal:  Dyn Med       Date:  2009-04-23

7.  Exploring the use of sensors to measure behavioral interactions: an experimental evaluation of using hand trajectories.

Authors:  Jeroen H M Bergmann; Patrick M Langdon; Ruth E Mayagoitia; Newton Howard
Journal:  PLoS One       Date:  2014-02-07       Impact factor: 3.240

8.  A novel motion tracking system for evaluation of functional rehabilitation of the upper limbs.

Authors:  Angel Gil-Agudo; Ana de Los Reyes-Guzmán; Iris Dimbwadyo-Terrer; Benito Peñasco-Martín; Alberto Bernal-Sahún; Patricia López-Monteagudo; Antonio Del Ama-Espinosa; José Luis Pons
Journal:  Neural Regen Res       Date:  2013-07-05       Impact factor: 5.135

9.  Joint Center Estimation Using Single-Frame Optimization: Part 1: Numerical Simulation.

Authors:  Eric Frick; Salam Rahmatalla
Journal:  Sensors (Basel)       Date:  2018-04-04       Impact factor: 3.576

10.  A Wearable Magneto-Inertial System for Gait Analysis (H-Gait): Validation on Normal Weight and Overweight/Obese Young Healthy Adults.

Authors:  Valentina Agostini; Laura Gastaldi; Valeria Rosso; Marco Knaflitz; Shigeru Tadano
Journal:  Sensors (Basel)       Date:  2017-10-21       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.