New technique for the determination of radon diffusion coefficient in radon-proof membranes.

M Jiránek1, A Fronka.   

Abstract

This paper describes a new device and a method to determine the radon diffusion coefficient in damp-proof membranes developed in the Czech Republic. The main advantage of the device is that it enables tests to be carried out in all the known measuring modes used throughout Europe. Two recently developed computer programs are presented for the numerical modelling of the time-dependent radon transport through damp-proof membranes. According to this method, the radon diffusion coefficient is derived from the process of fitting the numerical solution to the measured curve of radon concentration in a receiver container. Numerical simulation and measured data are also compared. Reasons for disagreements between different methods and specific configurations of the measuring device are also discussed.

Mesh:

Substances:

Year:  2008        PMID: 18397928     DOI: 10.1093/rpd/ncn121

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  1 in total

1.  Radon diffusion coefficients of vapour barrier membranes used in Canadian building construction.

Authors:  Jing Chen; Jim Ly; Eveline Schroth; Stan Hnatiuk; Etienne Frenette; Marie-France Blain
Journal:  Radiat Environ Biophys       Date:  2009-02-12       Impact factor: 1.925