Literature DB >> 1839631

Strain gauge method for measuring polymerization contraction of composite restoratives.

R L Sakaguchi1, C T Sasik, M A Bunczak, W H Douglas.   

Abstract

Post-gel polymerization contraction of composite restoratives produces a volumetric change in phase with the development of a modulus of elasticity and distributes contractile stresses through the resin hard tissue interface into the tooth. A new method for monitoring the polymerization contraction of composite restoratives utilizes electrical resistance strain gauges. The strain gauge system was calibrated with dial gauge measurements of the bulk expansion of gypsum products. Three composite types (microfilled, hybrid and posterior) were evaluated for polymerization exotherm, contraction during curing, and contraction for various shades. A 60-s curing time was used. The posterior composite (P-50) demonstrated the lowest exotherm and polymerization contraction. The contraction for Silux Plus dark grey was significantly lower than all other shades of all materials. The strain gauge method appears to be well suited for real-time measurement of the curing process and provides a means for studying the kinetics of polymerization.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1839631     DOI: 10.1016/0300-5712(91)90081-9

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  7 in total

1.  Shrinkage of dental composite in simulated cavity measured with digital image correlation.

Authors:  Jianying Li; Preetanjali Thakur; Alex S L Fok
Journal:  J Vis Exp       Date:  2014-07-21       Impact factor: 1.355

Review 2.  Polymerization shrinkage assessment of dental resin composites: a literature review.

Authors:  Dalia Kaisarly; Moataz El Gezawi
Journal:  Odontology       Date:  2016-08-19       Impact factor: 2.634

3.  Shrinkage Stresses Generated during Resin-Composite Applications: A Review.

Authors:  Luis Felipe J Schneider; Larissa Maria Cavalcante; Nick Silikas
Journal:  J Dent Biomech       Date:  2009-09-30

4.  Impact of similarity in chemical composition of light-polymerized resin composites on post-gel strains and interface integrity.

Authors:  Murat Cavit Cehreli; Zafer Cavit Cehreli; Kivanc Akca
Journal:  J Mater Sci Mater Med       Date:  2007-02-01       Impact factor: 4.727

5.  Comparison of variation in the light curing cycle with a time gap and its effect on polymerization shrinkage, degree of conversion and microhardness of a nanohybrid composite.

Authors:  Arunajatesan Subbiya; Newbegin Selvakumar Gold Pearlin Mary; Malathi Suresh; Paramasivam Vivekanandhan; Malarvizhi Dhakshinamoorthy; Vridhachalam Ganapathy Sukumaran
Journal:  J Conserv Dent       Date:  2015 Mar-Apr

Review 6.  Analytical methods for the measurement of polymerization kinetics and stresses of dental resin-based composites: A review.

Authors:  Mehrsima Ghavami-Lahiji; Tabassom Hooshmand
Journal:  Dent Res J (Isfahan)       Date:  2017 Jul-Aug

7.  Effect of low-shrinkage monomers on the physicochemical properties of experimental composite resin.

Authors:  Jingwei He; Sufyan Garoushi; Pekka K Vallittu; Lippo Lassila
Journal:  Acta Biomater Odontol Scand       Date:  2018-02-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.