A new safety device for hemodialysis.

Jarl Ahlmén1, Karl-Henrik Gydell, Henrik Hadimeri, Isabel Hernandez, Björn Rogland, Ulf Strömbom.   

Abstract

Accidental venous needle dislodgement during hemodialysis may cause serious bleeding including a sometimes fatal outcome. The venous pressure gauge of the dialysis monitor does not react when dislodgement occurs. A sensor patch put as an adhesive over the venous needle puncture site connected to an alarm unit by an optic fiber has been clinically tested in 5 dialysis departments. A small amount of blood on the sensor activates a light and sound alarm. A simple questionnaire was filled out by the nurses at each dialysis concerning their feeling of safety when the new device was used. Forty-one patients, mean age 65 years, have tested the new safety device. Two hundred test dialyses were studied, after exclusion of 13 tests. One hundred seventy-nine tests reacted positively on blood. In another 6 dialyses, a warning light appeared on the alarm unit indicating a failure in the sensor patch. Thus, the alarm functioned in 92.5% of all tests. After a small modification of the sensor patches there were only 2 dialyses (2/71) without an activated alarm on blood, i.e., 97.2% positive alarm reactions. The answers of the nurses indicated that they had an increased feeling of safety when using the new safety device, with a mean value of 3.4 points on a visual scale from 0 to 5 where 5 meant very much increased safety. In a situation when the dialysis monitors today do not react on bleedings from venous needle dislodgements, the new alarm safety device fulfils a known shortage in routine dialysis safety. In situations where supervision during a dialysis session may be insufficient as, for example, in home hemodialysis and self-care dialysis or in other situations when the patient is sleeping, the device may be life saving.

Entities:  

Mesh:

Year:  2008        PMID: 18394061     DOI: 10.1111/j.1542-4758.2008.00263.x

Source DB:  PubMed          Journal:  Hemodial Int        ISSN: 1492-7535            Impact factor:   1.812


  9 in total

1.  Study of light transmission through gauze pad effected by blood or liquids to detect needle dislodgement.

Authors:  Akihiro Takeuchi; Kai Ishida; Yasuo Morohoshi; Toshihiro Shinbo; Minoru Hirose; Noriaki Ikeda
Journal:  J Clin Monit Comput       Date:  2010-02       Impact factor: 2.502

2.  Renal Association Clinical Practice Guideline on Haemodialysis.

Authors:  Damien Ashby; Natalie Borman; James Burton; Richard Corbett; Andrew Davenport; Ken Farrington; Katey Flowers; James Fotheringham; R N Andrea Fox; Gail Franklin; Claire Gardiner; R N Martin Gerrish; Sharlene Greenwood; Daljit Hothi; Abdul Khares; Pelagia Koufaki; Jeremy Levy; Elizabeth Lindley; Jamie Macdonald; Bruno Mafrici; Andrew Mooney; James Tattersall; Kay Tyerman; Enric Villar; Martin Wilkie
Journal:  BMC Nephrol       Date:  2019-10-17       Impact factor: 2.388

Review 3.  Ambulatory Hemodialysis-Technology Landscape and Potential for Patient-Centered Treatment.

Authors:  Nina Hojs; William H Fissell; Shuvo Roy
Journal:  Clin J Am Soc Nephrol       Date:  2019-11-14       Impact factor: 8.237

Review 4.  Diagnosis, Treatment, and Prevention of Hemodialysis Emergencies.

Authors:  Manish Saha; Michael Allon
Journal:  Clin J Am Soc Nephrol       Date:  2016-11-09       Impact factor: 8.237

5.  Non-cladding optical fiber is available for detecting blood or liquids.

Authors:  Akihiro Takeuchi; Tomohiro Miwa; Masuo Shirataka; Minoru Sawada; Haruo Imaizumi; Hiroyuki Sugibuchi; Noriaki Ikeda
Journal:  J Clin Monit Comput       Date:  2010-08-10       Impact factor: 2.502

6.  Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch.

Authors:  Yi-Chun Du; Bee-Yen Lim; Wei-Siang Ciou; Ming-Jui Wu
Journal:  Sensors (Basel)       Date:  2016-06-09       Impact factor: 3.576

7.  Fabrication of a Textile-Based Wearable Blood Leakage Sensor Using Screen-Offset Printing.

Authors:  Ken-Ichi Nomura; Yoshinori Horii; Shusuke Kanazawa; Yasuyuki Kusaka; Hirobumi Ushijima
Journal:  Sensors (Basel)       Date:  2018-01-15       Impact factor: 3.576

8.  Optical and Electrical Characterization of Biocompatible Polymeric Lines for Hemodialysis Applications.

Authors:  Enrico Ravagli; Stefano Severi
Journal:  Materials (Basel)       Date:  2018-03-16       Impact factor: 3.623

9.  Real-Time Internet of Medical Things System for Detecting Blood Leakage during Hemodialysis Using a Novel Multiple Concentric Ring Sensor.

Authors:  Hsiang-Wei Hu; Chih-Hao Liu; Yi-Chun Du; Kuan-Yu Chen; Hsuan-Ming Lin; Chou-Ching Lin
Journal:  Sensors (Basel)       Date:  2022-03-03       Impact factor: 3.576