Literature DB >> 18393324

Automated FISH analysis using dual-fusion and break-apart probes on paraffin-embedded tissue sections.

Donát Alpár1, Judit Hermesz, László Pótó, Renáta László, László Kereskai, Pál Jáksó, Gábor Pajor, László Pajor, Béla Kajtár.   

Abstract

Detecting balanced translocations using tissue sections plays an important diagnostic role in cases of hematological malignancies. Manual scoring is often problematic due to truncation and overlapping of nuclei. Reports have described automated analysis using primarily tile sampling. The aim of this study was to investigate an automated fluorescent in situ hybridization analysis method using grid sampling on tissue sections, and compare the performance of dual-fusion (DF) and break-apart (BA) probes in this setting. Ten follicular, 10 mantle cell lymphoma, and 10 translocation-negative samples were used to set the threshold of false positivity using IGH/CCND1, IGH/BCL-2 DF, and IGH BA probes. The cut-off distances of red and green signals to define fusion signals were 0.5, 1.0, and 1.2 mum for the IGH/CCND1, IGH/BCL-2 DF, and IGH BA probes, respectively. The mean false positivity of grid units was 5.3, 11.4, and 28.1%, respectively. Ten to 14 additional samples analyzed blindly and were correctly classified using each probe. Discriminating positive and negative samples using automated analysis and grid sampling was possible with each probe, although different definitions of fusion signals were required due to the different physical distances between the DNA probes. Using the DF probes resulted in lower false positivity, which was less affected by signal numbers per grid units.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18393324     DOI: 10.1002/cyto.a.20557

Source DB:  PubMed          Journal:  Cytometry A        ISSN: 1552-4922            Impact factor:   4.355


  4 in total

1.  Gastrointestinal B-cell lymphomas: From understanding B-cell physiology to classification and molecular pathology.

Authors:  Xavier Sagaert; Thomas Tousseyn; Rhonda K Yantiss
Journal:  World J Gastrointest Oncol       Date:  2012-12-15

2.  Automated 3D scoring of fluorescence in situ hybridization (FISH) using a confocal whole slide imaging scanner.

Authors:  Ziv Frankenstein; Naohiro Uraoka; Umut Aypar; Ruth Aryeequaye; Mamta Rao; Meera Hameed; Yanming Zhang; Yukako Yagi
Journal:  Appl Microsc       Date:  2021-04-09

3.  FuseFISH: robust detection of transcribed gene fusions in single cells.

Authors:  Stefan Semrau; Nicola Crosetto; Magda Bienko; Marina Boni; Paolo Bernasconi; Roberto Chiarle; Alexander van Oudenaarden
Journal:  Cell Rep       Date:  2013-12-27       Impact factor: 9.423

4.  Validation of break-apart and fusion MYC probes using a digital fluorescence in situ hybridization capture and imaging system.

Authors:  Michael Liew; Leslie Rowe; Parker W Clement; Rodney R Miles; Mohamed E Salama
Journal:  J Pathol Inform       Date:  2016-05-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.