Literature DB >> 18384397

A retrospective analysis of early and delayed loading of full-arch mandibular prostheses using three different implant systems: clinical results with up to 5 years of loading.

Alf Eliasson1, Fredrik Blomqvist, Ann Wennerberg, Anders Johansson.   

Abstract

BACKGROUND: Early loading of implant-supported prostheses in the edentulous mandible is widely accepted, but do the clinical results replicate those of delayed loading?
PURPOSE: The aim of this study was to evaluate clinical outcome and patient satisfaction with early or delayed loading in patients treated with fixed prostheses, using three different implant systems.
MATERIALS AND METHODS: One hundred and nine consecutively treated patients received 490 implants supporting fixed prostheses; 82 patients with Brånemark System implants (Nobel Biocare AB, Göteborg, Sweden), 16 with Astra Tech implants (Astra Tech AB Dental Implant system, Mölndal, Sweden), and 11 with ITI MonoType implants (ITI Dental Implant System, Institute Straumann AG, Waldenburg, Switzerland). Prostheses were placed within 2 to 3 weeks in 55 patients; 54 patients underwent a two-stage procedure. Data were collected from patient records and radiographs; 83 patients attended a clinical examination and received a questionnaire.
RESULTS: All patients had fixed prostheses at follow-up with a mean observation time of 3.5 years. Cumulative survival rates (CSRs) were 92.5% of prostheses and 94.4% of implants for early loading, and 98.0 and 97.9% for delayed loading. The mean radiographic bone loss after the first year was small, and at 5 years less than 0.2 mm for both groups. With early loading, significantly more prostheses (p < .05) needed adjustment or replacement.
CONCLUSION: Statistically significantly more prostheses needed adjustment or replacement in the early group. The present study suggested lower CSRs for prostheses and implants in the early loading group after 5 years; the difference was not statistically significant. Larger study samples are needed to verify statistically small differences between treatment techniques.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18384397     DOI: 10.1111/j.1708-8208.2008.00099.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  5 in total

1.  The influence of immediately loaded implant treatment in the atrophic edentulous maxilla on oral health related quality of life of edentulous patients: 3-year results of a prospective study.

Authors:  Maria Erkapers; Susanna Segerström; Karl Ekstrand; Russell A Baer; Joseph A Toljanic; Andreas Thor
Journal:  Head Face Med       Date:  2017-11-10       Impact factor: 2.151

2.  The early loading of different surface-modified implants: a randomized clinical trial.

Authors:  Kinga Körmöczi; György Komlós; Petra Papócsi; Ferenc Horváth; Árpád Joób-Fancsaly
Journal:  BMC Oral Health       Date:  2021-04-26       Impact factor: 2.757

Review 3.  Immediate loading implants: review of the critical aspects.

Authors:  L Tettamanti; C Andrisani; M Andreasi Bassi; R Vinci; J Silvestre-Rangil; A Tagliabue
Journal:  Oral Implantol (Rome)       Date:  2017-09-27

4.  Clinical efficacy of early loading versus conventional loading of dental implants.

Authors:  Yanfei Zhu; Xinyi Zheng; Guanqi Zeng; Yi Xu; Xinhua Qu; Min Zhu; Eryi Lu
Journal:  Sci Rep       Date:  2015-11-06       Impact factor: 4.379

5.  Three-dimensional modeling of removal torque and fracture progression around implants.

Authors:  Kohei Murase; Patrik Stenlund; Peter Thomsen; Jukka Lausmaa; Anders Palmquist
Journal:  J Mater Sci Mater Med       Date:  2018-06-30       Impact factor: 3.896

  5 in total