Literature DB >> 18383461

Selective use of sonographic cervical length measurement for predicting imminent preterm delivery in women with preterm labor and intact membranes.

T Schmitz1, G Kayem, F Maillard, M-T Lebret, D Cabrol, F Goffinet.   

Abstract

OBJECTIVES: To determine, in a population of women with preterm labor and intact membranes, whether ultrasound cervical length measurement performed only in patients selected according to the Bishop score predicts imminent preterm delivery better than does systematic cervical length measurement in the entire population.
METHODS: The Bishop score and sonographic cervical length were recorded prospectively in women with preterm labor between 24 and 34 completed weeks' gestation. Outcome measures were preterm delivery within 48 h and within 7 days. Predictive values were calculated for each marker separately and then in combination.
RESULTS: Of the study population of 395 women, 17 (4.3%) and 32 (8.1%) delivered within 48 h and within 7 days, respectively, following inclusion. For delivery within 7 days, areas under the Bishop score (0.848) and sonographic cervical length (0.813) receiver-operating characteristics curves did not differ significantly. For the selective use of sonographic cervical length measurement in patients selected according to the Bishop score, the test was considered positive if the Bishop score was >or= 8, or 4-7 with cervical length <or= 30 mm. This test was as sensitive (94%) but more specific (60% vs. 42%, P < 0.001) for predicting preterm birth within 7 days than was sonographic cervical length with a 30-mm cut-off value in the entire population. Results were similar for delivery within 48 h.
CONCLUSION: For predicting imminent preterm delivery in women with preterm labor, measuring sonographic cervical length only in patients with a Bishop score between 4 and 7, compared with a strategy of systematic measurement in the entire population, reduces by 30% the number of false positives and might thus decrease unnecessary therapeutic intervention. Copyright (c) 2008 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2008        PMID: 18383461     DOI: 10.1002/uog.5297

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  3 in total

1.  Change in cervical length in cases resulting in threatened preterm labor.

Authors:  Toshiyuki Yoshizato; Hiroshi Tsujioka; Shinji Horiuchi; Kyoko Shirota; Hirotsugu Obama; Takeshi Nojiri; Fusanori Yotsumoto; Shingo Miyamato
Journal:  J Med Ultrason (2001)       Date:  2010-08-07       Impact factor: 1.314

2.  Mechanical and structural changes of the rat cervix in late-stage pregnancy.

Authors:  Michael J Poellmann; Edward K Chien; Barbara L McFarlin; Amy J Wagoner Johnson
Journal:  J Mech Behav Biomed Mater       Date:  2012-08-20

3.  Cost-effectiveness of diagnostic tests for threatened preterm labor in singleton pregnancy in France.

Authors:  Thomas Desplanches; Catherine Lejeune; Jonathan Cottenet; Paul Sagot; Catherine Quantin
Journal:  Cost Eff Resour Alloc       Date:  2018-06-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.