Literature DB >> 18383289

Pittfalls of MRI measurement of white matter perfusion based on arterial spin labeling.

P van Gelderen1, J A de Zwart, J H Duyn.   

Abstract

Although arterial spin labeling (ASL) MRI has been successfully applied to measure gray matter (GM) perfusion in vivo, accurate detection of white matter (WM) perfusion has proven difficult. Reported literature values are not consistent with each other or with perfusion measured with other modalities. In this work, the cause of these inconsistencies is investigated. The results suggest that WM perfusion values are substantially affected by the limited image resolution and by signal losses caused by the long transit times in WM, which significantly affect the label. From gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) bolus-tracking experiments (N=6), it is estimated that the transit time can be several seconds long in deep WM. Furthermore, simulations show that even at a spatial resolution of 7 microl voxel size, contamination by the GM signals can exceed 40% of the actual WM signal. From 10-min long flow-sensitive alternating inversion recovery ASL (FAIR-ASL) measurements at 3T in normal subjects (N=7), using highly sensitive detectors, it is shown that single-voxel (7 mul) deep WM perfusion values have an signal-to-noise ratio (SNR) less than 1. The poor sensitivity and heterogeneous transit time limit the applicability of ASL for measurement of perfusion in WM.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18383289     DOI: 10.1002/mrm.21515

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  97 in total

1.  Whole-brain cerebral blood flow mapping using 3D echo planar imaging and pulsed arterial tagging.

Authors:  Neville D Gai; S Lalith Talagala; John A Butman
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

2.  Comparison of relative cerebral blood flow maps using pseudo-continuous arterial spin labeling and single photon emission computed tomography.

Authors:  Peiying Liu; Jinsoo Uh; Michael D Devous; Bryon Adinoff; Hanzhang Lu
Journal:  NMR Biomed       Date:  2011-12-02       Impact factor: 4.044

3.  Arterial spin labeling in neuroimaging.

Authors:  Sasitorn Petcharunpaisan; Joana Ramalho; Mauricio Castillo
Journal:  World J Radiol       Date:  2010-10-28

4.  Resting quantitative cerebral blood flow in schizophrenia measured by pulsed arterial spin labeling perfusion MRI.

Authors:  Amy Pinkham; James Loughead; Kosha Ruparel; Wen-Chau Wu; Eve Overton; Raquel Gur; Ruben Gur
Journal:  Psychiatry Res       Date:  2011-08-09       Impact factor: 3.222

Review 5.  Revascularization of collaterals for hemodynamic stroke: insight on pathophysiology from the carotid occlusion surgery study.

Authors:  Jose G Romano; David S Liebeskind
Journal:  Stroke       Date:  2012-05-29       Impact factor: 7.914

6.  Accelerated white matter aging in schizophrenia: role of white matter blood perfusion.

Authors:  Susan Wright; Peter Kochunov; Joshua Chiappelli; Robert McMahon; Florian Muellerklein; S Andrea Wijtenburg; Michael G White; Laura M Rowland; L Elliot Hong
Journal:  Neurobiol Aging       Date:  2014-02-28       Impact factor: 4.673

7.  Three-dimensional acquisition of cerebral blood volume and flow responses during functional stimulation in a single scan.

Authors:  Ying Cheng; Peter C M van Zijl; James J Pekar; Jun Hua
Journal:  Neuroimage       Date:  2014-08-23       Impact factor: 6.556

8.  An Actively Decoupled Dual Transceiver Coil System for Continuous ASL at 7 T.

Authors:  Randall B Stafford; Myung-Kyun Woo; Se-Hong Oh; Sudipto Dolui; Tiejun Zhao; Young-Bo Kim; John A Detre; Zang-Hee Cho; Jongho Lee
Journal:  Int J Imaging Syst Technol       Date:  2016-06-16       Impact factor: 2.000

9.  Estimation of perfusion properties with MR Fingerprinting Arterial Spin Labeling.

Authors:  Katherine L Wright; Yun Jiang; Dan Ma; Douglas C Noll; Mark A Griswold; Vikas Gulani; Luis Hernandez-Garcia
Journal:  Magn Reson Imaging       Date:  2018-03-12       Impact factor: 2.546

10.  Reliability and precision of pseudo-continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O-water PET in elderly subjects at risk for Alzheimer's disease.

Authors:  Guofan Xu; Howard A Rowley; Gaohong Wu; David C Alsop; Ajit Shankaranarayanan; Maritza Dowling; Bradley T Christian; Terrence R Oakes; Sterling C Johnson
Journal:  NMR Biomed       Date:  2010-04       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.