Literature DB >> 18383270

Impact of clarification strategy on chromatographic separations: Pre-processing of cell homogenates.

D G Bracewell1, M Boychyn, H Baldascini, S A Storey, M Bulmer, J More, M Hoare.   

Abstract

This research focused on how the extent and type of primary solid-liquid separation can affect the performance of guard filtration and chromatography, in this instance hydrophobic interaction chromatography. The system used in the study was yeast (Saccharomyces cerevisiae) with the target molecule being an intracellular protein; alcohol dehydrogenase (ADH). As expected, loading more poorly clarified suspensions (both centrates and primary filtrates) required proportionally larger guard filtration areas. In addition for feed suspensions prepared by centrifugation, increased clarification led to greater column capacity. However, where filtration was used to achieve similar clarification considerably lower column capacity was achieved. These results were attributed to centrifugation leading to the aggregation of lipids and their subsequent removal in this form before application to the column. Clarification by filtration leaves such lipids in their original "soluble" state and hence they are not removed. The importance of the need to examine such interactive effects in bioprocess studies is discussed. This observation was confirmed with further analytical work into the nature of the aggregated material formed in the supernatant under centrifugation conditions. This material was only soluble in an organic solvent, and identified as phophatidylcholine and ergosterol as among the components removed by centrifugation and guard filtration as opposed to filtration and guard filtration. (c) 2008 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18383270     DOI: 10.1002/bit.21823

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  3 in total

Review 1.  Quality Control and Downstream Processing of Therapeutic Enzymes.

Authors:  David Gervais
Journal:  Adv Exp Med Biol       Date:  2019       Impact factor: 2.622

2.  In-column ATR-FTIR spectroscopy to monitor affinity chromatography purification of monoclonal antibodies.

Authors:  Maxime Boulet-Audet; Sergei G Kazarian; Bernadette Byrne
Journal:  Sci Rep       Date:  2016-07-29       Impact factor: 4.379

3.  Fouling of an anion exchange chromatography operation in a monoclonal antibody process: Visualization and kinetic studies.

Authors:  Edward J Close; Jeffrey R Salm; Timothy Iskra; Eva Sørensen; Daniel G Bracewell
Journal:  Biotechnol Bioeng       Date:  2013-03-31       Impact factor: 4.530

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.