PURPOSE: To investigate the feasibility of 7 T magnetic resonance imaging (MRI) to visualize and quantify trabecular bone structure in vivo by comparison with 3T MRI and in vivo three-dimensional (3D) high-resolution peripheral quantitative computed tomography (HR-pQCT). MATERIALS AND METHODS: The distal tibiae of 10 healthy volunteers were imaged. Therefore, fully balanced steady state free precession (bSSFP) and spin-echo (bSSSE) pulse sequences were implemented and optimized for 7 T. Structural bone parameters, such as apparent bone-volume over total-volume fraction (app.BV/TV), apparent trabecular plate separation (app.TbSp), apparent trabecular plate thickness (app.TbTh), and apparent trabecular plate number (app.TbN), were derived. RESULTS: All structural trabecular bone parameters correlated well (r > 0.6) between 7T and 3T, and between 7 T and HR-pQCT (r > 0.69), with the exception of app.TbTh, which correlated modestly (r = 0.41) between field strengths and very low with HR-pQCT (r < 0.16). Regarding absolute values, app.TbN varied only 4% between field strengths, and only 0.6% between 7 T and HR-pQCT. App.TbSp correlated best between 7 T and HR-pQCT (r = 0.89). Using bSSSE, significant smaller trabecular thickness and significant higher trabecular number were found compared to bSSFP. CONCLUSION: We concluded that imaging and quantification of the trabecular bone architecture at 7 T is feasible and preferably done using bSSSE. There exists great potential for ultra-high-field (UHF) MRI applied to trabecular bone measurements. (c) 2008 Wiley-Liss, Inc.
PURPOSE: To investigate the feasibility of 7 T magnetic resonance imaging (MRI) to visualize and quantify trabecular bone structure in vivo by comparison with 3T MRI and in vivo three-dimensional (3D) high-resolution peripheral quantitative computed tomography (HR-pQCT). MATERIALS AND METHODS: The distal tibiae of 10 healthy volunteers were imaged. Therefore, fully balanced steady state free precession (bSSFP) and spin-echo (bSSSE) pulse sequences were implemented and optimized for 7 T. Structural bone parameters, such as apparent bone-volume over total-volume fraction (app.BV/TV), apparent trabecular plate separation (app.TbSp), apparent trabecular plate thickness (app.TbTh), and apparent trabecular plate number (app.TbN), were derived. RESULTS: All structural trabecular bone parameters correlated well (r > 0.6) between 7T and 3T, and between 7 T and HR-pQCT (r > 0.69), with the exception of app.TbTh, which correlated modestly (r = 0.41) between field strengths and very low with HR-pQCT (r < 0.16). Regarding absolute values, app.TbN varied only 4% between field strengths, and only 0.6% between 7 T and HR-pQCT. App.TbSp correlated best between 7 T and HR-pQCT (r = 0.89). Using bSSSE, significant smaller trabecular thickness and significant higher trabecular number were found compared to bSSFP. CONCLUSION: We concluded that imaging and quantification of the trabecular bone architecture at 7 T is feasible and preferably done using bSSSE. There exists great potential for ultra-high-field (UHF) MRI applied to trabecular bone measurements. (c) 2008 Wiley-Liss, Inc.
Authors: Yusuf A Bhagat; Chamith S Rajapakse; Jeremy F Magland; James H Love; Alexander C Wright; Michael J Wald; Hee Kwon Song; Felix W Wehrli Journal: J Magn Reson Imaging Date: 2011-02 Impact factor: 4.813
Authors: Gregory Chang; Chamith S Rajapakse; James S Babb; Stephen P Honig; Michael P Recht; Ravinder R Regatte Journal: J Bone Miner Metab Date: 2011-11-30 Impact factor: 2.626
Authors: Yacine Noureddine; Andreas K Bitz; Mark E Ladd; Markus Thürling; Susanne C Ladd; Gregor Schaefers; Oliver Kraff Journal: MAGMA Date: 2015-09-26 Impact factor: 2.310
Authors: Fabio M Ulivieri; Barbara C Silva; Francesco Sardanelli; Didier Hans; John P Bilezikian; Renata Caudarella Journal: Endocrine Date: 2014-05-23 Impact factor: 3.633
Authors: Gregory Chang; Ding Xia; Orrin Sherman; Eric Strauss; Laith Jazrawi; Michael P Recht; Ravinder R Regatte Journal: MAGMA Date: 2013-05-09 Impact factor: 2.310
Authors: Roland Krug; Peder Eric Zufall Larson; Chunsheng Wang; Andrew J Burghardt; Douglas A C Kelley; Thomas M Link; Xiaoliang Zhang; Daniel B Vigneron; Sharmila Majumdar Journal: J Magn Reson Imaging Date: 2011-07-18 Impact factor: 4.813
Authors: Andrew G Webb; Christopher M Collins; Maarten J Versluis; Hermien E Kan; Nadine B Smith Journal: Magn Reson Med Date: 2010-02 Impact factor: 4.668