OBJECTIVES: To evaluate the feasibility of whole body imaging using a 3 Tesla magnetic resonance scanner without a contrast agent, and to study the prevalence of abnormal findings among a cohort of asymptomatic doctors. DESIGN: Prospective study. SETTING: Private hospital, Hong Kong. PARTICIPANTS: A total of 132 asymptomatic medical doctors (111 men, 21 women), with a mean age of 56 (range, 38-82) years, volunteered for the study. They underwent corresponding whole body imaging at our hospital between October 2005 and February 2006. Imaging involved a 3 Tesla magnetic resonance scanner with 32 channels, parallel imaging, Total Imaging Matrix technology, a maximum gradient amplitude of 40 mT/m and a slew rate of 200 mT/m/ms (Magnetom Tim Trio, Siemens Medical Solution, Erlangen, Germany). The use of matrix coils enabled coverage of the whole body. No contrast agent was used. MAIN OUTCOME MEASURES: Detection of abnormalities in asymptomatic, apparently healthy adults. RESULTS: All examinations were completed successfully. The mean scan time per subject was 33 (standard deviation, 4) minutes. All subjects tolerated the examination well and overall imaging quality was satisfactory. A total of 124 (94%) subjects had positive findings, of whom 24 (18%) had further workup. Five (4%) subjects were found to have tumours, of which two (1.5%) were proven malignant. Our cancer detection rate was comparable to that of other reported whole body screening studies using contrast magnetic resonance imaging and positron emission tomography. CONCLUSION: We demonstrated the feasibility of performing whole body imaging in 30 minutes, using 32-channel magnetic resonance imaging at 3 Tesla without a contrast agent or any ionising radiation.
OBJECTIVES: To evaluate the feasibility of whole body imaging using a 3 Tesla magnetic resonance scanner without a contrast agent, and to study the prevalence of abnormal findings among a cohort of asymptomatic doctors. DESIGN: Prospective study. SETTING: Private hospital, Hong Kong. PARTICIPANTS: A total of 132 asymptomatic medical doctors (111 men, 21 women), with a mean age of 56 (range, 38-82) years, volunteered for the study. They underwent corresponding whole body imaging at our hospital between October 2005 and February 2006. Imaging involved a 3 Tesla magnetic resonance scanner with 32 channels, parallel imaging, Total Imaging Matrix technology, a maximum gradient amplitude of 40 mT/m and a slew rate of 200 mT/m/ms (Magnetom Tim Trio, Siemens Medical Solution, Erlangen, Germany). The use of matrix coils enabled coverage of the whole body. No contrast agent was used. MAIN OUTCOME MEASURES: Detection of abnormalities in asymptomatic, apparently healthy adults. RESULTS: All examinations were completed successfully. The mean scan time per subject was 33 (standard deviation, 4) minutes. All subjects tolerated the examination well and overall imaging quality was satisfactory. A total of 124 (94%) subjects had positive findings, of whom 24 (18%) had further workup. Five (4%) subjects were found to have tumours, of which two (1.5%) were proven malignant. Our cancer detection rate was comparable to that of other reported whole body screening studies using contrast magnetic resonance imaging and positron emission tomography. CONCLUSION: We demonstrated the feasibility of performing whole body imaging in 30 minutes, using 32-channel magnetic resonance imaging at 3 Tesla without a contrast agent or any ionising radiation.
Authors: Oleh Dzyubachyk; Jorik Blaas; Charl P Botha; Marius Staring; Monique Reijnierse; Johan L Bloem; Rob J van der Geest; Boudewijn P F Lelieveldt Journal: Int J Comput Assist Radiol Surg Date: 2013-06-01 Impact factor: 2.924