Literature DB >> 18379873

Accuracy of the StressEraser in the detection of cardiac rhythms.

Keri J Heilman1, Mika Handelman, Gregory Lewis, Stephen W Porges.   

Abstract

StressEraser is a commercially marketed biofeedback device designed to enhance heart rate variability. StressEraser makes its internal calculations on beat-to-beat measures of finger pulse intervals. However, the accuracy and precision of StressEraser in quantifying interbeat intervals using finger pulse intervals has not been evaluated against standard laboratory equipment using R-R intervals. Accuracy was assessed by simultaneously recording interbeat intervals using StressEraser and a standard laboratory ECG system. The interbeat intervals were highly correlated between the systems. The average deviation in interbeat interval recordings between the systems was approximately 6 ms. Moreover, correlations approached unity between the systems on estimates of heart period, heart rate, and heart rate variability. Feedback from StressEraser is based on an interbeat time series that provides sufficient information to provide an excellent estimate of the dynamic changes in heart rate and heart rate variability. The slight variations between StressEraser and the laboratory equipment in quantifying heart rate and heart rate variability are due to features related to monitoring heart rate with finger pulse: (1) a lack in precision in the peak of the finger pulse relative to the clearly defined inflection point in the R-wave, and (2) contribution of variations in pulse transit time.

Entities:  

Mesh:

Year:  2008        PMID: 18379873     DOI: 10.1007/s10484-008-9054-1

Source DB:  PubMed          Journal:  Appl Psychophysiol Biofeedback        ISSN: 1090-0586


  9 in total

1.  Reliability of the BodyGuard2 (FirstBeat) in the Detection of Heart Rate Variability.

Authors:  Alyssa R Palmer; Rebecca Distefano; Keira Leneman; Daniel Berry
Journal:  Appl Psychophysiol Biofeedback       Date:  2021-09

Review 2.  Smart health monitoring systems: an overview of design and modeling.

Authors:  Mirza Mansoor Baig; Hamid Gholamhosseini
Journal:  J Med Syst       Date:  2013-01-15       Impact factor: 4.460

Review 3.  A comprehensive survey of wearable and wireless ECG monitoring systems for older adults.

Authors:  Mirza Mansoor Baig; Hamid Gholamhosseini; Martin J Connolly
Journal:  Med Biol Eng Comput       Date:  2013-01-19       Impact factor: 2.602

4.  Remotely supervised home-based online chair yoga intervention for older adults with dementia: Feasibility study.

Authors:  Juyoung Park; Keri J Heilman; Marlysa Sullivan; Jayshree Surage; Hannah Levine; Lillian Hung; María Ortega; Lisa Ann Kirk Wiese; Hyochol Ahn
Journal:  Complement Ther Clin Pract       Date:  2022-06-14       Impact factor: 3.577

5.  Assessing heart rate variability biofeedback as an adjunct to college recovery housing programs.

Authors:  David Eddie; Fiona N Conway; Nour Alayan; Jennifer Buckman; Marsha E Bates
Journal:  J Subst Abuse Treat       Date:  2018-06-28

6.  Meditation-induced changes in high-frequency heart rate variability predict smoking outcomes.

Authors:  Daniel J Libby; Patrick D Worhunsky; Corey E Pilver; Judson A Brewer
Journal:  Front Hum Neurosci       Date:  2012-03-19       Impact factor: 3.169

7.  Assessing mental stress from the photoplethysmogram: a numerical study.

Authors:  Peter H Charlton; Patrick Celka; Bushra Farukh; Phil Chowienczyk; Jordi Alastruey
Journal:  Physiol Meas       Date:  2018-05-15       Impact factor: 2.833

8.  Development of a modular stress management platform (Performance Edge VR) and a pilot efficacy trial of a bio-feedback enhanced training module for controlled breathing.

Authors:  Murielle G Kluge; Steven Maltby; Nicole Walker; Neanne Bennett; Eugene Aidman; Eugene Nalivaiko; Frederick Rohan Walker
Journal:  PLoS One       Date:  2021-02-02       Impact factor: 3.240

9.  Heart Rate Variability Biofeedback to Treat Anxiety in Young People With Autism Spectrum Disorder: Findings From a Home-Based Pilot Study.

Authors:  Helen Coulter; Mark Donnelly; John Mallett; W George Kernohan
Journal:  JMIR Form Res       Date:  2022-08-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.