Bioresorbable polylactide interbody implants in an ovine anterior cervical discectomy and fusion model: three-year results.

Kevin A Thomas1, Jeffrey M Toth, Neil R Crawford, Howard B Seim, Lewis L Shi, Mitchel B Harris, A Simon Turner.   

Abstract

STUDY
DESIGN: In vivo study of anterior discectomy and fusion using a bioresorbable 70:30 poly(l-lactide-co-d,l-lactide) interbody implant in an ovine model.
OBJECTIVE: To evaluate the efficacy of the polylactide implant to function as an interbody fusion device, and to assess the tissue reaction to the material during the resorption process. SUMMARY OF BACKGROUND DATA: The use of polylactide as a cervical interbody implant has several potential advantages when compared with traditional materials. Having an elastic modulus very similar to bone minimizes the potential for stress shielding, and as the material resorbs additional loading is transferred to the developing fusion mass. Although preclinical and clinical studies have demonstrated the suitability of polylactide implants for lumbar interbody fusion, detailed information on cervical anterior cervical discectomy and fusion (ACDF) with polylactide devices is desirable.
METHODS: Single level ACDF was performed in 8 skeletally mature ewes. Bioresorbable 70:30 poly (l-lactide-co-d,l-lactide) interbody implants packed with autograft were used with single-level metallic plates. Radiographs were made every 3 months up to 1 year, and yearly thereafter. The animals were killed at 6 months (3 animals), 12 months (3 animals), and 36 months (2 animals). In addition to the serial plain radiographs, the specimens were evaluated by nondestructive biomechanical testing and undecalcified histologic analysis.
RESULTS: The bioresorbable polylactide implants were effective in achieving interbody fusion. The 6-month animals appeared fused radiographically and biomechanically, whereas histologic sections demonstrated partial fusion (in 3 of 3 animals). Radiographic fusion was confirmed histologically and biomechanically at 12 months (3 of 3 animals) and 36 months (2 of 2 animals). A mild chronic inflammatory response to the resorbing polylactide implant was observed at both 6 months and 12 months. At 36 months, the operative levels were solidly fused and the implants were completely resorbed. No adverse tissue response was observed in any animal at any time period.
CONCLUSION: Interbody fusion was achieved using bioresorbable polylactide implants, with no evidence of implant collapse, extrusion, or adverse tissue response to the material. The use of polylactide as a cervical interbody device appears both safe and effective based on these ACDF animal model results.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18379399     DOI: 10.1097/BRS.0b013e3181695716

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  7 in total

1.  Static and dynamic fatigue behavior of topology designed and conventional 3D printed bioresorbable PCL cervical interbody fusion devices.

Authors:  Ashleen R Knutsen; Sean L Borkowski; Edward Ebramzadeh; Colleen L Flanagan; Scott J Hollister; Sophia N Sangiorgio
Journal:  J Mech Behav Biomed Mater       Date:  2015-05-27

2.  The use of BoneWelding® technology in spinal surgery: an experimental study in sheep.

Authors:  Dorothee Heidenreich; Jens D Langhoff; Katja Nuss; Katharina Kluge; Käthi Kämpf; Katalin Zlinsky; Monika Hilbe; Jörg Mayer; Brigitte von Rechenberg
Journal:  Eur Spine J       Date:  2011-04-27       Impact factor: 3.134

3.  Anterior cervical discectomy and fusion (ACDF) autograft versus graft substitutes: what do patients prefer?-A clinical study.

Authors:  Monish M Maharaj; Kevin Phan; Ralph J Mobbs
Journal:  J Spine Surg       Date:  2016-06

4.  In Vivo and In Vitro Study of a Polylactide-Fiber-Reinforced β-Tricalcium Phosphate Composite Cage in an Ovine Anterior Cervical Intercorporal Fusion Model.

Authors:  Janek Frantzén; Aliisa Pälli; Esa Kotilainen; Harri Heino; Bettina Mannerström; Heini Huhtala; Hannu Kuokkanen; George K Sándor; Kari Leino; Matias Röyttä; Riitta Parkkola; Riitta Suuronen; Susanna Miettinen; Hannu T Aro; Suvi Haimi
Journal:  Int J Biomater       Date:  2011-10-26

5.  Preliminary results in anterior cervical discectomy and fusion with an experimental bioabsorbable cage - clinical and radiological findings in an ovine animal model.

Authors:  Dorothea Daentzer; Thilo Floerkemeier; Ivonne Bartsch; Waseem Masalha; Bastian Welke; Christof Hurschler; Theresa Kauth; Daniel Kaltbeitzel; Christian Hopmann; Bernd Kujat; Katharina Kalla
Journal:  Springerplus       Date:  2013-08-29

6.  Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study.

Authors:  Lu Cao; Qian Chen; Li-Bo Jiang; Xiao-Fan Yin; Chong Bian; Hui-Ren Wang; Yi-Qun Ma; Xiang-Qian Li; Xi-Lei Li; Jian Dong
Journal:  Int J Nanomedicine       Date:  2017-10-03

7.  Biomechanical Analysis of Biodegradable Cervical Plates Developed for Anterior Cervical Discectomy and Fusion.

Authors:  Pyung Goo Cho; Gyu Yeul Ji; Sang Hyuk Park; Dong Ah Shin
Journal:  Asian Spine J       Date:  2018-10-16
  7 in total