Literature DB >> 18378380

Ultrasound-enhanced thrombolysis using Definity as a cavitation nucleation agent.

Saurabh Datta1, Constantin-C Coussios, Azzdine Y Ammi, T Douglas Mast, Gabrielle M de Courten-Myers, Christy K Holland.   

Abstract

Ultrasound has been shown previously to act synergistically with a thrombolytic agent, such as recombinant tissue plasminogen activator (rt-PA) to accelerate thrombolysis. In this in vitro study, a commercial contrast agent, Definity, was used to promote and sustain the nucleation of cavitation during pulsed ultrasound exposure at 120 kHz. Ultraharmonic signals, broadband emissions and harmonics of the fundamental were measured acoustically by using a focused hydrophone as a passive cavitation detector and used to quantify the level of cavitation activity. Human whole blood clots suspended in human plasma were exposed to a combination of rt-PA, Definity and ultrasound at a range of ultrasound peak-to-peak pressure amplitudes, which were selected to expose clots to various degrees of cavitation activity. Thrombolytic efficacy was determined by measuring clot mass loss before and after the treatment and correlated with the degree of cavitation activity. The penetration depth of rt-PA and plasminogen was also evaluated in the presence of cavitating microbubbles using a dual-antibody fluorescence imaging technique. The largest mass loss (26.2%) was observed for clots treated with 120-kHz ultrasound (0.32-MPa peak-to-peak pressure amplitude), rt-PA and stable cavitation nucleated by Definity. A significant correlation was observed between mass loss and ultraharmonic signals (r = 0.85, p < 0.0001, n = 24). The largest mean penetration depth of rt-PA (222 microm) and plasminogen (241 microm) was observed in the presence of stable cavitation activity. Stable cavitation activity plays an important role in enhancement of thrombolysis and can be monitored to evaluate the efficacy of thrombolytic treatment.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18378380      PMCID: PMC2945910          DOI: 10.1016/j.ultrasmedbio.2008.01.016

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  38 in total

1.  Whole blood clot lysis in newborns and adults after adding different concentrations of recombinant tissue plasminogen activator (Rt-PA).

Authors:  B Trusen; M Ries; M Zenker; M Rauh; E Beinder; H Keuper; D Harms
Journal:  Semin Thromb Hemost       Date:  1998       Impact factor: 4.180

2.  The effect of 40 kHz ultrasound on tissue plasminogen activator-induced clot lysis in three in vitro models.

Authors:  Marlien Pieters; Rob T Hekkenberg; Marrie Barrett-Bergshoeff; Dingeman C Rijken
Journal:  Ultrasound Med Biol       Date:  2004-11       Impact factor: 2.998

3.  Ultrasound-induced blood clot dissolution without a thrombolytic drug is more effective with lower frequencies.

Authors:  Max Nedelmann; Christian Brandt; Felicitas Schneider; B Martin Eicke; Oliver Kempski; Frank Krummenauer; Marianne Dieterich
Journal:  Cerebrovasc Dis       Date:  2005-05-30       Impact factor: 2.762

4.  Enhancement of fibrinolysis with 40-kHz ultrasound.

Authors:  V Suchkova; F N Siddiqi; E L Carstensen; D Dalecki; S Child; C W Francis
Journal:  Circulation       Date:  1998-09-08       Impact factor: 29.690

5.  Effectiveness of lipid microbubbles and ultrasound in declotting thrombosis.

Authors:  Feng Xie; Jeane M Tsutsui; John Lof; Evan C Unger; Jason Johanning; William C Culp; Terry Matsunaga; Thomas R Porter
Journal:  Ultrasound Med Biol       Date:  2005-07       Impact factor: 2.998

6.  Low-frequency, low-intensity ultrasound accelerates thrombolysis through the skull.

Authors:  S Behrens; M Daffertshofer; D Spiegel; M Hennerici
Journal:  Ultrasound Med Biol       Date:  1999-02       Impact factor: 2.998

7.  Transcranial low-frequency ultrasound-mediated thrombolysis in brain ischemia: increased risk of hemorrhage with combined ultrasound and tissue plasminogen activator: results of a phase II clinical trial.

Authors:  Michael Daffertshofer; Achim Gass; Peter Ringleb; Matthias Sitzer; Ulrich Sliwka; Thomas Els; Oliver Sedlaczek; Walter J Koroshetz; Michael G Hennerici
Journal:  Stroke       Date:  2005-06-09       Impact factor: 7.914

8.  Low-frequency ultrasound penetrates the cranium and enhances thrombolysis in vitro.

Authors:  M Akiyama; T Ishibashi; T Yamada; H Furuhata
Journal:  Neurosurgery       Date:  1998-10       Impact factor: 4.654

9.  Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke.

Authors:  Andrei V Alexandrov; Carlos A Molina; James C Grotta; Zsolt Garami; Shiela R Ford; Jose Alvarez-Sabin; Joan Montaner; Maher Saqqur; Andrew M Demchuk; Lemuel A Moyé; Michael D Hill; Anne W Wojner
Journal:  N Engl J Med       Date:  2004-11-18       Impact factor: 91.245

10.  Ultrasound affects distribution of plasminogen and tissue-type plasminogen activator in whole blood clots in vitro.

Authors:  Branka Devcic-Kuhar; Stefan Pfaffenberger; Lisa Gherardini; Christoph Mayer; Martin Gröschl; Christoph Kaun; Ewald Benes; Erwin Tschachler; Kurt Huber; Gerald Maurer; Johann Wojta; Michael Gottsauner-Wolf
Journal:  Thromb Haemost       Date:  2004-11       Impact factor: 5.249

View more
  92 in total

1.  In vivo therapeutic gas delivery for neuroprotection with echogenic liposomes.

Authors:  George L Britton; Hyunggun Kim; Patrick H Kee; Jaroslaw Aronowski; Christy K Holland; David D McPherson; Shao-Ling Huang
Journal:  Circulation       Date:  2010-10-04       Impact factor: 29.690

2.  Combined contrast-enhanced ultrasound and rt-PA treatment is safe and improves impaired microcirculation after reperfusion of middle cerebral artery occlusion.

Authors:  Max Nedelmann; Nouha Ritschel; Simone Doenges; Alexander C Langheinrich; Till Acker; Peter Reuter; Mesut Yeniguen; Jan Pukropski; Manfred Kaps; Clemens Mueller; Georg Bachmann; Tibo Gerriets
Journal:  J Cereb Blood Flow Metab       Date:  2010-06-09       Impact factor: 6.200

3.  Ultrasound-mediated tumor imaging and nanotherapy using drug loaded, block copolymer stabilized perfluorocarbon nanoemulsions.

Authors:  Natalya Rapoport; Kweon-Ho Nam; Roohi Gupta; Zhongao Gao; Praveena Mohan; Allison Payne; Nick Todd; Xin Liu; Taeho Kim; Jill Shea; Courtney Scaife; Dennis L Parker; Eun-Kee Jeong; Anne M Kennedy
Journal:  J Control Release       Date:  2011-01-26       Impact factor: 9.776

4.  Acoustic characterization of echogenic liposomes: frequency-dependent attenuation and backscatter.

Authors:  Jonathan A Kopechek; Kevin J Haworth; Jason L Raymond; T Douglas Mast; Stephen R Perrin; Melvin E Klegerman; Shaoling Huang; Tyrone M Porter; David D McPherson; Christy K Holland
Journal:  J Acoust Soc Am       Date:  2011-11       Impact factor: 1.840

5.  Passive imaging with pulsed ultrasound insonations.

Authors:  Kevin J Haworth; T Douglas Mast; Kirthi Radhakrishnan; Mark T Burgess; Jonathan A Kopechek; Shao-Ling Huang; David D McPherson; Christy K Holland
Journal:  J Acoust Soc Am       Date:  2012-07       Impact factor: 1.840

6.  Determination of postexcitation thresholds for single ultrasound contrast agent microbubbles using double passive cavitation detection.

Authors:  Daniel A King; Michael J Malloy; Alayna C Roberts; Alexander Haak; Christian C Yoder; William D O'Brien
Journal:  J Acoust Soc Am       Date:  2010-06       Impact factor: 1.840

7.  Regional and Conducted Vascular Effects of Endovascular Ultrasound Catheters.

Authors:  Matthew A Muller; Aris Xie; Yue Qi; Yan Zhao; Koya Ozawa; Misty Noble-Vranish; Jonathan R Lindner
Journal:  Ultrasound Med Biol       Date:  2020-06-08       Impact factor: 2.998

8.  Spatial specificity and sensitivity of passive cavitation imaging for monitoring high-intensity focused ultrasound thermal ablation in ex vivo bovine liver.

Authors:  Kevin Haworth; Vasant A Salgaonkar; Nicholas M Corregan; Christy K Holland; T D Mast
Journal:  Proc Meet Acoust       Date:  2013-06-02

9.  On the relationship between microbubble fragmentation, deflation and broadband superharmonic signal production.

Authors:  Brooks D Lindsey; Juan D Rojas; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2015-03-09       Impact factor: 2.998

10.  Integrated Histotripsy and Bubble Coalescence Transducer for Thrombolysis.

Authors:  Aiwei Shi; Jonathan Lundt; Zilin Deng; Jonathan Macoskey; Hitinder Gurm; Gabe Owens; Xi Zhang; Timothy L Hall; Zhen Xu
Journal:  Ultrasound Med Biol       Date:  2018-09-30       Impact factor: 2.998

View more